OFFICIAL FAULT CODESelection Error (Display: Err / Impossible)
Electrolux
Electrolux // OFFICIAL DIAGNOSTIC BENCH

Electrolux Selection Error (Display: Err / Impossible)

DryerGeneral System & Mechanical Integration

Symptom / Description

FAULT

On TC2, TC3, TC4 user interfaces, the text 'Err' flashes in the area displaying the cycle duration numbers. On the TC1 user interface, the message 'Impossible' appears on the text line. The buzzer does not emit a specific melody, and the Start/Pause LED does not flash as on older platforms. This signal is displayed for approximately 1 second.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

1. An option key incompatible with the selected wash program is pressed. 2. An option key is pressed or the selector is moved during an active cycle.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Avoid pressing option keys that are incompatible with the currently selected program. Do not press option keys or turn the selector while a cycle is in progress.
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Electrolux Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLGeneral System & Mechanical IntegrationTumble Dryer
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Nominal Resistance (Ω)
Earth Ground Continuity: <0.1Ω (Chassis metal to mains plug earth pin). Mains: 230V AC ±10%.NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Protective Earth Bonding & Incoming Mains Voltage
Test Pins & Connections
PROBE (+)
PROBE (-)
Between unpainted chassis metal and mains plug earth pin; incoming terminal block L-N
Tolerance & Diagnostic CriteriaProtective conductor impedance must remain <0.1Ω. Line voltage 207V–253V AC under load.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect electrical mains plug or trip dedicated circuit breaker before servicing.
  • !Wait at least 5 minutes before opening any casing panels to reset volatile microcontrollers and bleed residual charges.
  • !Operate in a dry workshop environment; never bypass internal electrical thermal cutouts.
3. Preliminary Mechanical & Visual Checks
  • Check appliance leveling with a spirit level; adjust threaded leveling feet for perfect stability.
  • Check door and lid perimeter rubber gaskets for tears, gaps, or foreign object obstruction.
  • Inspect shock absorbers, suspension springs, and rubber dampers for mechanical fatigue or excessive play.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Electrolux SELECTION ERROR (DISPLAY: ERR / IMPOSSIBLE)

FAQ TREE
What does error code SELECTION ERROR (DISPLAY: ERR / IMPOSSIBLE) mean on a Electrolux appliance?

Electrolux SELECTION ERROR (DISPLAY: ERR / IMPOSSIBLE): On TC2, TC3, TC4 user interfaces, the text 'Err' flashes in the area displaying the cycle duration numbers. On the TC1 user interface, the message 'Impossible' appears on the text line. The buzzer does not emit a specific melody, and the Start/Pause LED does not flash as on older platforms. This signal is displayed for approximately 1 second.

What is the root cause of Electrolux error code SELECTION ERROR (DISPLAY: ERR / IMPOSSIBLE)?

1. An option key incompatible with the selected wash program is pressed. 2. An option key is pressed or the selector is moved during an active cycle.

How do I fix or resolve Electrolux error code SELECTION ERROR (DISPLAY: ERR / IMPOSSIBLE)?

Avoid pressing option keys that are incompatible with the currently selected program. Do not press option keys or turn the selector while a cycle is in progress.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // ELECTROLUX

Related Electrolux Tumble Dryer Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

Water Tank Full AlertDrainage System & Drain Pump
The full condensation water tank alarm is automatically displayed at the end of each cycle.
Inspect Protocol
AdGeneral System & Mechanical Integration
Auto-dry circuit malfunction.
Inspect Protocol
Condensation Water Tank Full AlarmDrainage System & Drain Pump
An alarm (indicated by 'Alerte relative au bac d’eau de condensation') is automatically disp...
Inspect Protocol
Condenser Cleaning WarningGeneral System & Mechanical Integration
A warning alert is displayed regarding the condenser (as indicated by 'Condenser Cleaning Al...
Inspect Protocol
E60Heating Element, Thermostat & Safety Fuse
Clothes are not drying, no heat.
Inspect Protocol
E63Heating Element, Thermostat & Safety Fuse
Heater shorted to ground.
Inspect Protocol
E64Heating Element, Thermostat & Safety Fuse
Heater open circuit (most common call).
Inspect Protocol
EH0General System & Mechanical Integration
Appliance will not start or has no power.
Inspect Protocol
EHEElectronic Control Board (PCB) & Bus Communications
Appliance is dead or has intermittent power.
Inspect Protocol
ErrGeneral System & Mechanical Integration
The screen displays "Err" and the Start/Pause indicator light flashes.
Inspect Protocol
F71NTC Temperature Sensor & Thermistor
NTC humidity sensor error in the air exhaust duct.
Inspect Protocol
F72NTC Temperature Sensor & Thermistor
Condenser NTC sensor error near the compressor.
Inspect Protocol
F73NTC Temperature Sensor & Thermistor
Steam generator NTC sensor error.
Inspect Protocol
Lint Filter Cleaning WarningGeneral System & Mechanical Integration
A warning alert is displayed regarding the lint filter (as indicated by 'Lint Filter Cleanin...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy