Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Franke F18
FAQ TREEWhat does error code F18 mean on a Franke appliance?
Franke error code F18 indicates: Franke Mythos / Maris / Frames by Franke Built-in Pyrolytic & Combi-Steam Oven: Diagnostic fault code F18 registered by the microcomputer controller. Supply voltage too low (<185 VAC under heating load).
What is the root cause of Franke error code F18?
The primary root cause for Franke code F18 is: On Franke appliances engineered with Swiss high-precision thermal management with dual tangential cooling turbine, PT500/PT1000 platinum RTD cavity sensor, motorized pyrolytic door lock, and Ghost Touch interface: high impedance neutral or undersized line cable Metrological tolerance verification: voltage < 185V AC RMS under load...
How do I fix or resolve Franke error code F18?
To resolve error code F18: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure AC line voltage at terminal block with all elements energized. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn function selector to Off (0). Disconnect mains power breaker for 60 seconds. Restore power, touch and hold Clock and Plus (+) keys for 5 seconds until the display beeps and shows '0:00', then reset current time.
Is it safe to clear Franke error code F18 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Franke code F18 persists, the physical component causing On Franke appliances engineered with Swiss high-precision thermal management with dual tangential cooling turbine, PT500/PT1000 platinum RTD cavity sensor, motorized pyrolytic door lock, and Ghost Touch interface: high impedance neutral or undersized line cable Metrological tolerance verification: voltage < 185V AC RMS under load.. must be inspected or replaced.
How do I test electrical resistance for Franke code F18 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..
What safety protocol must be followed before servicing Franke code F18?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?



