Kitchenaid F3 E1 — Dishwasher
[ACTIVE]KitchenAid Architect & KDFE/KDTE FreeFlex Third Rack Dishwasher: Thermistor NTC water temperature sensor fault F3 E1; wash cycle runs excessively long or water fails to reach sanitize temp.
On Kitchenaid dishwashers (KitchenAid premium culinary engineering, Clean Water Wash micro-filtration, and Even-Heat precision controls): NTC sensor open circuit (>200 kΩ) or shorted (<500 Ω), defective optical water indicator (OWI) housing, or loose harness.
Unplug dishwasher. Measure NTC thermistor resistance on OWI sensor: nominal 46–52 kΩ at 20°C (68°F), 9.5–11.5 kΩ at 60°C (140°F). Replace OWI if out of range. Press 3 selected keys in sequence 1-2-3, 1-2-3, 1-2-3 with less than 1 second between presses. All display LEDs light; close door to run rapid diagnostic wash.