OFFICIAL FAULT CODEH
Samet
Samet // OFFICIAL DIAGNOSTIC BENCH

Samet H

HobGeneral System & Mechanical Integration
Integrated luxury convection oven and induction cooktop with illuminated touch controls
Hob
Other Brands Sharing Code H:BoschHSamsungHAEGHIndesitHHaierHBauknechtHHooverHHisenseHFAGORHSchaub LorenzH

Symptom / Description

FAULT

Samet H: Operational cycle fault detected during Hob / Cooktop program execution.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

The cooking zone is still hot to the touch after being turned off.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1This is a safety feature, not an error. Do not touch the cooking zone until the 'H' disappears.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Samet Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLGeneral System & Mechanical IntegrationHob / Cooktop
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
Earth Ground Continuity: <0.1Ω (Chassis metal to mains plug earth pin). Mains: 230V AC ±10%.NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Protective Earth Bonding & Incoming Mains Voltage
Test Pins & Connections
PROBE (+)
PROBE (-)
Between unpainted chassis metal and mains plug earth pin; incoming terminal block L-N
Tolerance & Diagnostic CriteriaProtective conductor impedance must remain <0.1Ω. Line voltage 207V–253V AC under load.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect electrical mains plug or trip dedicated circuit breaker before servicing.
  • !Wait at least 5 minutes before opening any casing panels to reset volatile microcontrollers and bleed residual charges.
  • !Operate in a dry workshop environment; never bypass internal electrical thermal cutouts.
3. Preliminary Mechanical & Visual Checks
  • Check appliance leveling with a spirit level; adjust threaded leveling feet for perfect stability.
  • Check door and lid perimeter rubber gaskets for tears, gaps, or foreign object obstruction.
  • Inspect shock absorbers, suspension springs, and rubber dampers for mechanical fatigue or excessive play.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Samet H

FAQ TREE
What does error code H mean on a Samet appliance?

Samet error code H indicates: Samet H: Operational cycle fault detected during Hob / Cooktop program execution..

What is the root cause of Samet error code H?

The primary root cause for Samet code H is: The cooking zone is still hot to the touch after being turned off..

How do I fix or resolve Samet error code H?

To resolve error code H: This is a safety feature, not an error. Do not touch the cooking zone until the 'H' disappears.

Is it safe to clear Samet error code H by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Samet code H persists, the physical component causing The cooking zone is still hot to the touch after being turned off. must be inspected or replaced.

How do I test electrical resistance for Samet code H using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Protective Earth Bonding & Incoming Mains Voltage across Between unpainted chassis metal and mains plug earth pin; incoming terminal block L-N. Expected nominal reading is Earth Ground Continuity: <0.1Ω (Chassis metal to mains plug earth pin). Mains: 230V AC ±10%.. Tolerance: Protective conductor impedance must remain <0.1Ω. Line voltage 207V–253V AC under load..

What safety protocol must be followed before servicing Samet code H?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // SAMET

Related Samet Hob / Cooktop Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E1General System & Mechanical Integration
Samet E1: Operational cycle fault detected during Hob / Cooktop program execution.
Inspect Protocol
E2NTC Temperature Sensor & Thermistor
Samet E2: NTC temperature sensor signal out of range (open or short circuit) in Hob / Cooktop.
Inspect Protocol
E3General System & Mechanical Integration
Samet E3: Operational cycle fault detected during Hob / Cooktop program execution.
Inspect Protocol
E4Electronic Control Board (PCB) & Bus Communications
Communication error between modules
Inspect Protocol
E5Electronic Control Board (PCB) & Bus Communications
Samet E5: Operational cycle fault detected during Hob / Cooktop program execution.
Inspect Protocol
E6Electronic Control Board (PCB) & Bus Communications
Samet E6: Operational cycle fault detected during Hob / Cooktop program execution.
Inspect Protocol
FGeneral System & Mechanical Integration
Cookware not detected (flashing)
Inspect Protocol
HIGeneral System & Mechanical Integration
Water turbidity sensor error
Inspect Protocol
PFGeneral System & Mechanical Integration
Samet PF: Operational cycle fault detected during Refrigerator / Freezer program execution.
Inspect Protocol
SAFEDoor Lock Mechanism & Safety Interlock
Oven is in safety lock mode
Inspect Protocol
SRRefrigeration Compressor, Defrost Heater & PTC Relay
System running continuously
Inspect Protocol
A01General System & Mechanical Integration
Samet A01: Operational cycle fault detected during Oven / Microwave program execution.
Inspect Protocol
C7Heating Element, Thermostat & Safety Fuse
Washing machine motor overheating
Inspect Protocol
CFElectronic Control Board (PCB) & Bus Communications
Samet CF: Operational cycle fault detected during Refrigerator / Freezer program execution.
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy