[ACTIVE]AEG Lavatherm / SensiDry / AbsoluteCare Heat-Pump: Moisture sensing error E30; the electronic control detects abnormal conductance signals from drum sensing strips.
On AEG (AEG Lavatherm / SensiDry / AbsoluteCare Heat-Pump) models: Worn carbon sensing brushes on drum perimeter, oxidized stainless steel drum rib contacts, calcified sensing strips, or broken signal cable to main board.