AEG E60 — Dryer
[ACTIVE]AEG Lavatherm / SensiDry / AbsoluteCare Heat-Pump: Heating system general failure E60; air inside drum remains cold and cycle runs excessively long without drying clothes.
On AEG (AEG Lavatherm / SensiDry / AbsoluteCare Heat-Pump) models: Open heating element coils (dual element: ~25 Ω and ~35 Ω), tripped manual/automatic safety thermostat, defective heating relay on PCB, or compressor fault in heat pump.
Disconnect dryer and remove rear heating duct cover. Measure resistance of both heating elements with ohmmeter. Check continuity through safety thermostats (< 1 Ω). Rotate selector to 12 o'clock (OFF), press and hold Start/Pause and Exit simultaneously for 4 seconds until the diagnostic LED sequence resets error memory.