OEM VERIFIED BENCH
OFFICIAL FAULT CODEPU
Airlux
Airlux // OFFICIAL DIAGNOSTIC BENCH

Airlux PU

Air ConditionerDrive Motor, Inverter & Tachometer Sensor
Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum
Air Conditioner
Other Brands Sharing Code PU:Gree / MacePU

Symptom / Description

FAULT

Capacitor charge malfunction

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

Defective 3-Phase Motor Windings / Tacho Generator / Carbon Brushes, open/short circuit in the wiring harness, or faulty connector on the drive motor, inverter & tachometer sensor.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Check inverter board capacitor and charging circuit.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Airlux Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDrive Motor, Inverter & Tachometer SensorAir Conditioner / Heat Pump
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
3Ω–6Ω (BLDC phase U-V-W) / 60Ω–180Ω (Tacho coil) / 1.5Ω–3.5Ω (Universal stator)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Test Pins & Connections
PROBE (+)
PROBE (-)
Across phase pins U-V, V-W, U-W on motor harness; across tacho pins
Tolerance & Diagnostic CriteriaBLDC phase winding values must be strictly balanced within ±0.3Ω. Hand rotation generates 1V–4V AC on tacho.
1. Pre-Intervention Electrical Safety Protocols
  • !High-Voltage Safety Protocol & DC Bus: Wait at least 5 minutes after power cutoff to allow inverter DC bus capacitors (380V DC) to bleed down.
  • !Verify 0V DC across inverter filter capacitors before unplugging motor harness connectors.
  • !Keep hands clear of drive belt and pulleys during any manual rotation tng.
3. Preliminary Mechanical & Visual Checks
  • Slip off drive belt and spin drum/motor shaft by hand to check for roaring or seized ball bearings.
  • For universal motors: verify carbon brushes have at least 10mm remaining length and smooth contact faces.
  • Inspect motor suspension rubber mounts and drive belt tension/groove profile.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Airlux PU

FAQ TREE
What does error code PU mean on a Airlux appliance?

Airlux error code PU indicates: Capacitor charge malfunction.

What is the root cause of Airlux error code PU?

The primary root cause for Airlux code PU is: Defective 3-Phase Motor Windings / Tacho Generator / Carbon Brushes, open/short circuit in the wiring harness, or faulty connector on the drive motor, inverter & tachometer sensor..

How do I fix or resolve Airlux error code PU?

To resolve error code PU: Check inverter board capacitor and charging circuit.

Is it safe to clear Airlux error code PU by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Airlux code PU persists, the physical component causing Defective 3-Phase Motor Windings / Tacho Generator / Carbon Brushes, open/short circuit in the wiring harness, or faulty connector on the drive motor, inverter & tachometer sensor. must be inspected or replaced.

How do I test electrical resistance for Airlux code PU using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test 3-Phase Motor Windings / Tacho Generator / Carbon Brushes across Across phase pins U-V, V-W, U-W on motor harness; across tacho pins. Expected nominal reading is 3Ω–6Ω (BLDC phase U-V-W) / 60Ω–180Ω (Tacho coil) / 1.5Ω–3.5Ω (Universal stator). Tolerance: BLDC phase winding values must be strictly balanced within ±0.3Ω. Hand rotation generates 1V–4V AC on tacho..

What safety protocol must be followed before servicing Airlux code PU?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // AIRLUX

Related Airlux Air Conditioner / Heat Pump Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

U1Electronic Control Board (PCB) & Bus Communications
Compressor phase current detection circuit malfunction
Inspect Protocol
U2Electronic Control Board (PCB) & Bus Communications
Compressor protection against loss of phase
Inspect Protocol
U3Electronic Control Board (PCB) & Bus Communications
PN voltage drop protection
Inspect Protocol
U4Electronic Control Board (PCB) & Bus Communications
Compressor reverse protection
Inspect Protocol
U5Electronic Control Board (PCB) & Bus Communications
AC current detect circuit malfunction
Inspect Protocol
U7Electronic Control Board (PCB) & Bus Communications
4-way valve reversal abnormal
Inspect Protocol
U8NTC Temperature Sensor & Thermistor
Disconnection of the exhaust temperature sensor
Inspect Protocol
U9Electronic Control Board (PCB) & Bus Communications
AC power zero voltage detect error
Inspect Protocol
b5Electronic Control Board (PCB) & Bus Communications
Inlet tube sensor malfunction
Inspect Protocol
b7Electronic Control Board (PCB) & Bus Communications
Outlet tube sensor malfunction
Inspect Protocol
C5Electronic Control Board (PCB) & Bus Communications
Jumper cap malfunction protection
Inspect Protocol
E1General System & Mechanical Integration
Refrigerant system high pressure protection
Inspect Protocol
E2NTC Temperature Sensor & Thermistor
Evaporator anti-freezing protection activated on the air conditioning unit.
Inspect Protocol
E4NTC Temperature Sensor & Thermistor
Compressor exhaust high temperature protection
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy