Ariston F02 — Dryer
[ACTIVE]Ariston Hotpoint-Ariston Aqualtis Heat Pump Tumble Dryer: Drum drive motor stalled or thermal protector tripped F02; motor winding overheats and internal bimetallic klixon opens.
On Ariston tumble dryers: Seized drum support rollers, broken idler pulley bearing, defective motor run capacitor (10–16 µF), or jammed blower fan wheel.
Rotate drum by hand to check for mechanical binding. Test motor run capacitor with capacitance meter (10–16 µF). Check motor winding resistance (20–35 Ω). Hold Start/Pause key for 5 seconds until indicator extinguishes, rotate program dial to 0, and clean lint trap.