Ariston F06 — Dryer
[ACTIVE]Ariston Hotpoint-Ariston Aqualtis Heat Pump Tumble Dryer: Drum rotation tachometer pulse failure F06; motor runs but microcomputer receives no tachometric feedback within 5 seconds.
On Ariston tumble dryers: Broken poly-V drive belt, loose motor shaft tachometer magnet, disconnected tach harness plug, or worn idler tension spring.
Inspect drum drive belt tension around motor spindle and drum perimeter. Measure tachometer generator coil resistance (nominal 115–170 Ω). Replace belt if broken. Hold Start/Pause key for 5 seconds until indicator extinguishes, rotate program dial to 0, and clean lint trap.