[ACTIVE]Ariston Active Oxygen Total NoFrost Refrigerator / Freezer: Diagnostic code F5E2 indicates dispenser ice chute motorized flapper door failed to open or close; air leaks frost the chute.
On Ariston refrigerators (Ariston Aqualtis and HD Defrost electronic platform architecture): Stripped gears in stepper drive motor, broken return spring, or open motor coil. Stepper winding resistance: 200–450 Ω.
Disconnect power. Remove dispenser facade. Inspect ice chute flapper for mechanical ice obstruction. Measure coil resistance of stepper motor: expect 200–450 Ω across phases. Replace motorized door actuator assembly if gears are stripped. Hold Alarm Reset pad for 5 seconds until audible alert ceases and active cooling LED illuminates steady.