Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Arthur Martin E35
FAQ TREEWhat does error code E35 mean on a Arthur Martin appliance?
Arthur Martin error code E35 indicates: Arthur Martin Electrolux AWF Series / Silence Plus Washer: Water overfill safety protection active E35; water level exceeds maximum safety limit and triggers safety drain..
What is the root cause of Arthur Martin error code E35?
The primary root cause for Arthur Martin code E35 is: On Arthur Martin (Arthur Martin Electrolux AWF Series / Silence Plus Washer) models: Solenoid inlet valve mechanically stuck open due to sand or limescale, triac on main PCB short-circuited continuously powering inlet valve, or air tube disconnected..
How do I fix or resolve Arthur Martin error code E35?
To resolve error code E35: Shut off household water tap immediately. Unplug appliance. If water continues flowing while unplugged, replace mechanical inlet valve. Check triac voltage (0V when idle). Hold Départ/Pause and Option buttons firmly for 5 seconds until the red indicator extinguishes and service memory resets.
Is it safe to clear Arthur Martin error code E35 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Arthur Martin code E35 persists, the physical component causing On Arthur Martin (Arthur Martin Electrolux AWF Series / Silence Plus Washer) models: Solenoid inlet valve mechanically stuck open due to sand or limescale, triac on main PCB short-circuited continuously powering inlet valve, or air tube disconnected. must be inspected or replaced.
How do I test electrical resistance for Arthur Martin code E35 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Mechanical Pressure Switch Contacts / Inductive Frequency Sensor across Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal. Expected nominal reading is Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.. Tolerance: Mechanical switch contacts must transition cleanly on gentle breath pressure. Coil ~22Ω ±5%..
What safety protocol must be followed before servicing Arthur Martin code E35?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?



