Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEE62
Arthur Martin
Arthur Martin // OFFICIAL DIAGNOSTIC BENCH

Arthur Martin Tumble Dryer E62

DryerNTC Temperature Sensor & Thermistor
High-efficiency heat pump tumble dryer with ergonomic titanium drum and digital sensor display
Dryer
Select Appliance Type
0ms Instant Telemetry Switch
Electrolux Group: Equivalent Code Across OEM Group Brands
EWM / EDW / EDR Shared Electronic Architecture
AEGE62ElectroluxE62ZanussiE62FaureE62ZoppasE62CastorE62
Other Brands Sharing Code E62:ForsE62FrigidaireE62KoenicE62MerkerE62MideaE62

Symptom / Description

FAULT

Arthur Martin ADE / ADC Series / Envol Automatique Dryer: Overheating alarm E62; drum temperature exceeds maximum safety limit (> 95°C) and cycle halts immediately.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Arthur Martin (Arthur Martin ADE / ADC Series / Envol Automatique Dryer) models: Stuck closed heating relay contact on PCB (continuous power to heater), blocked lint filter stopping heat dissipation, or defective forward duct NTC sensor.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Inspect heating relay on control board (ensure contacts open when unpowered, resistance ∞ Ω). Clean all lint filters and measure front duct NTC resistance (~5–6 kΩ at 25°C). Hold Départ/Pause and Option buttons firmly for 5 seconds until the red indicator extinguishes and service memory resets.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Arthur Martin Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Thermal & Heating Loop

Calrod Heating Element R1, Safety Klixon & NTC Thermistor Probe

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III24.6 ΩVΩCOMHEATING ELEMENT R1HEATER R1: 20-28 ΩSAFETY THERMOSTAT (KLIXON)NTC SENSOR (4.8-12kΩ)
Target Component
NTC Temperature Sensor Probe (Thermistor)
Nominal Resistance / Test Range
4.8kΩ–12kΩ (at 20°C–25°C)
Test Harness Pins
Across sensor pins 1-2 (unplugged harness)
Diagnostic Verification Rule
Zero or OL indicates open heating element or tripped safety thermostat. Check insulation to earth.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorTumble Dryer
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Arthur Martin E62

FAQ TREE
What does error code E62 mean on a Arthur Martin appliance?

Arthur Martin error code E62 indicates: Arthur Martin ADE / ADC Series / Envol Automatique Dryer: Overheating alarm E62; drum temperature exceeds maximum safety limit (> 95°C) and cycle halts immediately..

What is the root cause of Arthur Martin error code E62?

The primary root cause for Arthur Martin code E62 is: On Arthur Martin (Arthur Martin ADE / ADC Series / Envol Automatique Dryer) models: Stuck closed heating relay contact on PCB (continuous power to heater), blocked lint filter stopping heat dissipation, or defective forward duct NTC sensor..

How do I fix or resolve Arthur Martin error code E62?

To resolve error code E62: Inspect heating relay on control board (ensure contacts open when unpowered, resistance ∞ Ω). Clean all lint filters and measure front duct NTC resistance (~5–6 kΩ at 25°C). Hold Départ/Pause and Option buttons firmly for 5 seconds until the red indicator extinguishes and service memory resets.

Is it safe to clear Arthur Martin error code E62 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Arthur Martin code E62 persists, the physical component causing On Arthur Martin (Arthur Martin ADE / ADC Series / Envol Automatique Dryer) models: Stuck closed heating relay contact on PCB (continuous power to heater), blocked lint filter stopping heat dissipation, or defective forward duct NTC sensor. must be inspected or replaced.

How do I test electrical resistance for Arthur Martin code E62 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Arthur Martin code E62?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

What does Arthur Martin error code E62 mean on a Tumble Dryer?

Arthur Martin error code E62 on a Tumble Dryer indicates: Arthur Martin ADE / ADC Series / Envol Automatique Dryer: Overheating alarm E62; drum temperature exceeds maximum safety limit (> 95°C) and cycle halts immediately.. Primary cause: On Arthur Martin (Arthur Martin ADE / ADC Series / Envol Automatique Dryer) models: Stuck closed heating relay contact on PCB (continuous power to heater), blocked lint filter stopping heat dissipation, or defective forward duct NTC sensor.. Recommended solution: Inspect heating relay on control board (ensure contacts open when unpowered, resistance ∞ Ω). Clean all lint filters and measure front duct NTC resistance (~5–6 kΩ at 25°C). Hold Départ/Pause and Option buttons firmly for 5 seconds until the red indicator extinguishes and service memory resets..

What does Arthur Martin error code E62 mean on a Washing Machine?

Arthur Martin error code E62 on a Washing Machine indicates: Arthur Martin Electrolux AWF Series / Silence Plus Washer: Water overheating alarm E62; wash temperature exceeds 88°C for > 5 minutes triggering safety cutoff.. Primary cause: On Arthur Martin (Arthur Martin Electrolux AWF Series / Silence Plus Washer) models: Heating element power relay contact welded closed on main PCB (continuous unswitched 230V power), shorted wash NTC sensor, or MCU logic fault.. Recommended solution: Turn machine off immediately. Measure voltage at heating terminals with program off (must be 0V AC; if 230V AC is present, replace stuck relay / PCB!). Test NTC sensor. Hold Départ/Pause and Option buttons firmly for 5 seconds until the red indicator extinguishes and service memory resets..

Community Verification

COMMUNITY

Did this solution resolve the issue?

Arthur Martin E62 — Multi-Appliance Technical Reference

Verified OEM diagnostic specifications across all appliance systems sharing this fault code.

Arthur Martin E62 — Dryer

[ACTIVE]
Symptom / Description:

Arthur Martin ADE / ADC Series / Envol Automatique Dryer: Overheating alarm E62; drum temperature exceeds maximum safety limit (> 95°C) and cycle halts immediately.

Root Cause:

On Arthur Martin (Arthur Martin ADE / ADC Series / Envol Automatique Dryer) models: Stuck closed heating relay contact on PCB (continuous power to heater), blocked lint filter stopping heat dissipation, or defective forward duct NTC sensor.

Repair Instructions:

Inspect heating relay on control board (ensure contacts open when unpowered, resistance ∞ Ω). Clean all lint filters and measure front duct NTC resistance (~5–6 kΩ at 25°C). Hold Départ/Pause and Option buttons firmly for 5 seconds until the red indicator extinguishes and service memory resets.

Arthur Martin E62 — Washing Machine

Symptom / Description:

Arthur Martin Electrolux AWF Series / Silence Plus Washer: Water overheating alarm E62; wash temperature exceeds 88°C for > 5 minutes triggering safety cutoff.

Root Cause:

On Arthur Martin (Arthur Martin Electrolux AWF Series / Silence Plus Washer) models: Heating element power relay contact welded closed on main PCB (continuous unswitched 230V power), shorted wash NTC sensor, or MCU logic fault.

Repair Instructions:

Turn machine off immediately. Measure voltage at heating terminals with program off (must be 0V AC; if 230V AC is present, replace stuck relay / PCB!). Test NTC sensor. Hold Départ/Pause and Option buttons firmly for 5 seconds until the red indicator extinguishes and service memory resets.

SEMANTIC KNOWLEDGE GRAPH // ARTHUR MARTIN

Related Arthur Martin Tumble Dryer Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E63Tumble Dryer
Heating Element, Thermostat & Safety Fuse
Arthur Martin ADE / ADC Series / Envol Automatique Dryer: Safety thermostat tripped E63; one...
Inspect Protocol
E70Tumble Dryer
NTC Temperature Sensor & Thermistor
Arthur Martin ADE / ADC Series / Envol Automatique Dryer: Temperature sensor NTC general err...
Inspect Protocol
E71Tumble Dryer
NTC Temperature Sensor & Thermistor
Arthur Martin ADE / ADC Series / Envol Automatique Dryer: Heater duct NTC sensor fault E71; ...
Inspect Protocol
E72Tumble Dryer
NTC Temperature Sensor & Thermistor
Arthur Martin ADE / ADC Series / Envol Automatique Dryer: Condenser / evaporator NTC error E...
Inspect Protocol
E73Tumble Dryer
NTC Temperature Sensor & Thermistor
Arthur Martin ADE / ADC Series / Envol Automatique Dryer: Compressor discharge NTC sensor fa...
Inspect Protocol
E80Tumble Dryer
Electronic Control Board (PCB) & Bus Communications
Arthur Martin ADE / ADC Series / Envol Automatique Dryer: Program cycle selector encoder err...
Inspect Protocol
E90Tumble Dryer
Electronic Control Board (PCB) & Bus Communications
Arthur Martin ADE / ADC Series / Envol Automatique Dryer: Electronic communication general f...
Inspect Protocol
E91Tumble Dryer
Electronic Control Board (PCB) & Bus Communications
Arthur Martin ADE / ADC Series / Envol Automatique Dryer: User interface board communication...
Inspect Protocol
E92Tumble Dryer
Electronic Control Board (PCB) & Bus Communications
Arthur Martin ADE / ADC Series / Envol Automatique Dryer: Firmware protocol mismatch E92; co...
Inspect Protocol
E93Tumble Dryer
Electronic Control Board (PCB) & Bus Communications
Arthur Martin ADE / ADC Series / Envol Automatique Dryer: Configuration checksum error E93; ...
Inspect Protocol
EH0Tumble Dryer
General System & Mechanical Integration
Arthur Martin ADE / ADC Series / Envol Automatique Dryer: Electrical mains supply out of lim...
Inspect Protocol
E30Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor
Arthur Martin ADE / ADC Series / Envol Automatique Dryer: Moisture sensing error E30; the el...
Inspect Protocol
E31Tumble Dryer
Electronic Control Board (PCB) & Bus Communications
Arthur Martin ADE / ADC Series / Envol Automatique Dryer: Conductance sensor frequency out o...
Inspect Protocol
E32Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor
Arthur Martin ADE / ADC Series / Envol Automatique Dryer: Conductance sensor signal unstable...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy