Bauknecht F22 — Dryer
[ACTIVE]Bauknecht SuperEco & PremiumCare Heat Pump Tumble Dryer: Heat pump compressor discharge overtemperature warning F22; high-pressure line thermistor exceeds 115°C safety ceiling.
On Bauknecht heat pump dryers: Severely blocked bottom condenser filter choking airflow, slow evaporator blower fan, or micro-leak in R134a/R290 gas circuit.
Clean or replace lower foam condenser filter block. Vacuum aluminum heat exchanger fins. Verify secondary cooling fan operates freely during drying. Rotate selector dial to 6 o'clock, press Start 3 times, rotate to 7 o'clock, press Start 3 times.