Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Bompani A17
FAQ TREEWhat does error code A17 mean on a Bompani appliance?
Bompani error code A17 indicates: Bompani AquaStop Fully Integrated & Freestanding Eco-Wash Dishwasher: Operational diagnostic fault code A17 signaled by internal electronics. Sump water siphoning condition detected (flowmeter increments pulses without corresponding level rise).
What is the root cause of Bompani error code A17?
The primary root cause for Bompani code A17 is: On Bompani kitchen suites engineered with synchronous wash pump with run capacitor, 1800W flow-through heater (26-28 Ω), pneumatic pressure switch, optical turbidity sensor, and AquaStop tray switch: Drain hose discharge end pushed too deeply into standpipe or installed below minimum 40cm height Multimeter diagnostic parameter: drain hose apex must rise to minimum 65cm to 85cm above floor level with anti-siphon siphon breaker valve..
How do I fix or resolve Bompani error code A17?
To resolve error code A17: Safely de-energize the appliance at the electrical distribution board. Unplug wiring connector from the affected component and verify with a digital multimeter: inspect physical drain hose geometry behind machine and test water level switch state during slow water fill. Inspect spade lugs for signs of heat discoloration. Replace defective component, restore electrical supply, and perform system reset: Switch appliance off. Press and hold Start/Reset button for 4 seconds while powering on, release when LED flashes rapidly, clearing saved cycle errors.
Is it safe to clear Bompani error code A17 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Bompani code A17 persists, the physical component causing On Bompani kitchen suites engineered with synchronous wash pump with run capacitor, 1800W flow-through heater (26-28 Ω), pneumatic pressure switch, optical turbidity sensor, and AquaStop tray switch: Drain hose discharge end pushed too deeply into standpipe or installed below minimum 40cm height Multimeter diagnostic parameter: drain hose apex must rise to minimum 65cm to 85cm above floor level with anti-siphon siphon breaker valve. must be inspected or replaced.
How do I test electrical resistance for Bompani code A17 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Mechanical Pressure Switch Contacts / Inductive Frequency Sensor across Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal. Expected nominal reading is Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.. Tolerance: Mechanical switch contacts must transition cleanly on gentle breath pressure. Coil ~22Ω ±5%..
What safety protocol must be followed before servicing Bompani code A17?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?