Brandt d16 — Dryer
[ACTIVE]Brandt Malice / Condensation & Heat Pump Tumble Dryer: Door latch open during cycle d16; cycle pauses immediately as door contact microswitch opens during active operation.
On Brandt tumble dryers utilizing Malice top-loading thermodynamic drying circuit, electronic condenser monitoring, and bi-directional drum tumbling: Worn door catch pin, loose latch microswitch mounting bracket, or broken door strike tongue.
Inspect door catch alignment and latch engagement. Test door microswitch continuity (~0 Ω closed, infinite open) with a multimeter. Turn cycle selector to Stop, press and hold Start and Delay Start together for 5 seconds until a double beep sounds, then return to Off.