Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEE13
Candy
Candy // OFFICIAL DIAGNOSTIC BENCH

Candy Tumble Dryer E13

DryerGeneral System & Mechanical Integration
High-efficiency heat pump tumble dryer with ergonomic titanium drum and digital sensor display
Dryer
Select Appliance Type
0ms Instant Telemetry Switch
Haier / Candy / Hoover / GE Group: Equivalent Code Across OEM Group Brands
Haier Europe / Candy-Hoover Shared Electronic Platform
HaierE13HooverE13RosièresE13ZerowattE13IbernaE13GEE13
Other Brands Sharing Code E13:BoschE13SiemensE13SamsungE13LGE13ElectroluxE13AEGE13BekoE13NeffE13V-ZugE13

Symptom / Description

FAULT

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Condensate collection container full alert E13; water reservoir float switch trips and halts program execution.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Candy tumble dryers utilizing RapidÓ heat-pump thermodynamic circuit, 7-sensor electronic moisture tracking, and hOn remote diagnostics: Water container completely filled with extracted condensate, stuck microswitch lever, or slime coating the float.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Empty condensate drawer completely and re-insert firmly until it clicks. If code persists empty, clean sump float switch chamber in lower rear. Switch selector to Off, press and hold Start and Delay Start together for 5 seconds until buzzer beeps twice, then turn to 12 o'clock.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Candy Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Water Inlet, Aquastop & Flowmeter Loop

Inlet Solenoid Valve Y1, Reed Turbine Flowmeter & Aquastop Float S2

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III3.84 kΩVΩCOMINLET VALVE Y1SOLENOID Y1: 4.0 kΩFLOWMETER B1 (REED)AQUASTOP SWITCH S2: 0.0Ω
Target Component
Protective Earth Bonding & Incoming Mains Voltage
Nominal Resistance / Test Range
Earth Ground Continuity: <0.1Ω (Chassis metal to mains plug earth pin). Mains: 230V AC ±10%.
Test Harness Pins
Between unpainted chassis metal and mains plug earth pin; incoming terminal block L-N
Diagnostic Verification Rule
OL on solenoid indicates open coil. Closed contact on float switch S2 indicates base pan leak.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLGeneral System & Mechanical IntegrationTumble Dryer
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
Earth Ground Continuity: <0.1Ω (Chassis metal to mains plug earth pin). Mains: 230V AC ±10%.NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Protective Earth Bonding & Incoming Mains Voltage
Test Pins & Connections
PROBE (+)
PROBE (-)
Between unpainted chassis metal and mains plug earth pin; incoming terminal block L-N
Tolerance & Diagnostic CriteriaProtective conductor impedance must remain <0.1Ω. Line voltage 207V–253V AC under load.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect electrical mains plug or trip dedicated circuit breaker before servicing.
  • !Wait at least 5 minutes before opening any casing panels to reset volatile microcontrollers and bleed residual charges.
  • !Operate in a dry workshop environment; never bypass internal electrical thermal cutouts.
3. Preliminary Mechanical & Visual Checks
  • Check appliance leveling with a spirit level; adjust threaded leveling feet for perfect stability.
  • Check door and lid perimeter rubber gaskets for tears, gaps, or foreign object obstruction.
  • Inspect shock absorbers, suspension springs, and rubber dampers for mechanical fatigue or excessive play.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Candy E13

FAQ TREE
What does error code E13 mean on a Candy appliance?

Candy error code E13 indicates: Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Condensate collection container full alert E13; water reservoir float switch trips and halts program execution..

What is the root cause of Candy error code E13?

The primary root cause for Candy code E13 is: On Candy tumble dryers utilizing RapidÓ heat-pump thermodynamic circuit, 7-sensor electronic moisture tracking, and hOn remote diagnostics: Water container completely filled with extracted condensate, stuck microswitch lever, or slime coating the float..

How do I fix or resolve Candy error code E13?

To resolve error code E13: Empty condensate drawer completely and re-insert firmly until it clicks. If code persists empty, clean sump float switch chamber in lower rear. Switch selector to Off, press and hold Start and Delay Start together for 5 seconds until buzzer beeps twice, then turn to 12 o'clock.

Is it safe to clear Candy error code E13 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Candy code E13 persists, the physical component causing On Candy tumble dryers utilizing RapidÓ heat-pump thermodynamic circuit, 7-sensor electronic moisture tracking, and hOn remote diagnostics: Water container completely filled with extracted condensate, stuck microswitch lever, or slime coating the float. must be inspected or replaced.

How do I test electrical resistance for Candy code E13 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Protective Earth Bonding & Incoming Mains Voltage across Between unpainted chassis metal and mains plug earth pin; incoming terminal block L-N. Expected nominal reading is Earth Ground Continuity: <0.1Ω (Chassis metal to mains plug earth pin). Mains: 230V AC ±10%.. Tolerance: Protective conductor impedance must remain <0.1Ω. Line voltage 207V–253V AC under load..

What safety protocol must be followed before servicing Candy code E13?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

What does Candy error code E13 mean on a Tumble Dryer?

Candy error code E13 on a Tumble Dryer indicates: Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Condensate collection container full alert E13; water reservoir float switch trips and halts program execution.. Primary cause: On Candy tumble dryers utilizing RapidÓ heat-pump thermodynamic circuit, 7-sensor electronic moisture tracking, and hOn remote diagnostics: Water container completely filled with extracted condensate, stuck microswitch lever, or slime coating the float.. Recommended solution: Empty condensate drawer completely and re-insert firmly until it clicks. If code persists empty, clean sump float switch chamber in lower rear. Switch selector to Off, press and hold Start and Delay Start together for 5 seconds until buzzer beeps twice, then turn to 12 o'clock..

What does Candy error code E13 mean on a Washing Machine?

Candy error code E13 on a Washing Machine indicates: Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Bus communication fault E13; user interface display panel loses serial handshake with main chassis power board.. Primary cause: On Candy washing machines featuring Speed-Drive Inverter brushless motor, Smart Touch NFC / hOn Wi-Fi connectivity, and GIAS Cuore electronic platform: Corroded ribbon cable edge connectors, electrical noise spikes, or defective 5V DC low-voltage rail on main board.. Recommended solution: Inspect wiring harness between display and main power board for continuity and terminal crimp tension. Verify 5V DC and 12V DC test points on power PCB. Turn dial to Off, press and hold Start/Pause and Extra Rinse simultaneously for 5 seconds until display flashes '888', then power cycle..

Community Verification

COMMUNITY

Did this solution resolve the issue?

Candy E13 — Multi-Appliance Technical Reference

Verified OEM diagnostic specifications across all appliance systems sharing this fault code.

Candy E13 — Dryer

[ACTIVE]
Symptom / Description:

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Condensate collection container full alert E13; water reservoir float switch trips and halts program execution.

Root Cause:

On Candy tumble dryers utilizing RapidÓ heat-pump thermodynamic circuit, 7-sensor electronic moisture tracking, and hOn remote diagnostics: Water container completely filled with extracted condensate, stuck microswitch lever, or slime coating the float.

Repair Instructions:

Empty condensate drawer completely and re-insert firmly until it clicks. If code persists empty, clean sump float switch chamber in lower rear. Switch selector to Off, press and hold Start and Delay Start together for 5 seconds until buzzer beeps twice, then turn to 12 o'clock.

Candy E13 — Washing Machine

Symptom / Description:

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Bus communication fault E13; user interface display panel loses serial handshake with main chassis power board.

Root Cause:

On Candy washing machines featuring Speed-Drive Inverter brushless motor, Smart Touch NFC / hOn Wi-Fi connectivity, and GIAS Cuore electronic platform: Corroded ribbon cable edge connectors, electrical noise spikes, or defective 5V DC low-voltage rail on main board.

Repair Instructions:

Inspect wiring harness between display and main power board for continuity and terminal crimp tension. Verify 5V DC and 12V DC test points on power PCB. Turn dial to Off, press and hold Start/Pause and Extra Rinse simultaneously for 5 seconds until display flashes '888', then power cycle.

SEMANTIC KNOWLEDGE GRAPH // CANDY

Related Candy Tumble Dryer Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E14Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Condensate lift pump motor fault E14; ...
Inspect Protocol
E15Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Inverter compressor driver fault E15; ...
Inspect Protocol
E16Tumble Dryer
General System & Mechanical Integration
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Heat pump evaporator coil freezing ale...
Inspect Protocol
E17Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Drum drive belt breakage detected E17;...
Inspect Protocol
E18Tumble Dryer
General System & Mechanical Integration
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Power supply voltage or frequency faul...
Inspect Protocol
E21Tumble Dryer
General System & Mechanical Integration
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Moisture sensing calibration amplifier...
Inspect Protocol
F1Tumble Dryer
NTC Temperature Sensor & Thermistor
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Air intake temperature sensor fault F1...
Inspect Protocol
F2Tumble Dryer
NTC Temperature Sensor & Thermistor
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Rear exhaust temperature sensor fault ...
Inspect Protocol
F3Tumble Dryer
NTC Temperature Sensor & Thermistor
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Compressor discharge pipe high-tempera...
Inspect Protocol
F4Tumble Dryer
Water Level Pressure Switch & Air Dome
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Condensate evacuation pump failure F4;...
Inspect Protocol
F5Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Motor / compressor inverter communicat...
Inspect Protocol
F6Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Auxiliary heat-pump cooling fan fault ...
Inspect Protocol
E01Tumble Dryer
Heating Element, Thermostat & Safety Fuse
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Airflow restriction warning E01; door ...
Inspect Protocol
E02Tumble Dryer
NTC Temperature Sensor & Thermistor
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Process air duct NTC sensor error E02;...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy