Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEER22
Candy
Candy // OFFICIAL DIAGNOSTIC BENCH

Candy Hob ER22

HobDoor Lock Mechanism & Safety Interlock
Integrated luxury convection oven and induction cooktop with illuminated touch controls
Hob
Select Appliance Type
0ms Instant Telemetry Switch
Haier / Candy / Hoover / GE Group: Equivalent Code Across OEM Group Brands
Haier Europe / Candy-Hoover Shared Electronic Platform
HaierER22HooverER22RosièresER22ZerowattER22IbernaER22GEER22
Other Brands Sharing Code ER22:GaggenauER22AirluxER22AtlanticER-22BaumaticER22ElicaER22FaberER22ForsER22

Symptom / Description

FAULT

Candy Moderna / Idea / Smart Touch Induction Cooktop: Touch control evaluation hardware fault ER22; capacitive sensing integrated circuit detects an internal analog front-end failure.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Candy cooktops utilizing Moderna & Idea high-frequency induction power generator, electromagnetic pan detection, and capacitive touch interface: Conductive liquid leakage inside the chassis onto touch sensor PCB, broken capacitive spring pin, or static discharge damage.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Open hob housing. Inspect touch sensor PCB for liquid stains or corrosion. Clean contacts with isopropyl alcohol. Replace touch PCB if hardware damaged. Wipe glass surface completely dry, power down circuit breaker for 60 seconds, restore supply and touch Key Lock for 5 seconds.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Candy Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Door Interlock & Triac Loop

PTC Bi-metal Solenoid L1, Microswitch S1 & PCB Switching Triac TY1

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III320.0 ΩVΩCOMDOOR INTERLOCK L1PTC / SOLENOID COIL L1LOCKING BOLT PINSAFETY MICROSWITCH S1
Target Component
PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Nominal Resistance / Test Range
800Ω–1.5kΩ (PTC terminals L-N) / 60Ω–120Ω (Pulse Solenoid)
Test Harness Pins
Across PTC heater terminals on lock bezel; switch contact reads <0.2Ω when locked
Diagnostic Verification Rule
High resistance (> 2 kΩ) or failed contact closure prevents cycle initiation and locks MCU bus.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDoor Lock Mechanism & Safety InterlockHob / Cooktop
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
800Ω–1.5kΩ (PTC terminals L-N) / 60Ω–120Ω (Pulse Solenoid)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Test Pins & Connections
PROBE (+)
PROBE (-)
Across PTC heater terminals on lock bezel; switch contact reads <0.2Ω when locked
Tolerance & Diagnostic Criteria±15%. Switch contacts must read open (OL) when unlocked and 0.0Ω–0.2Ω when fully latched.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V mains power before releasing door gasket clamp or lock retaining screws.
  • !Never short-circuit or bypass the safety door lock contacts: severe hazard of rotating drum exposure or fire.
  • !Keep fingers away from spring-loaded latch mechanisms during closure cycling.
3. Preliminary Mechanical & Visual Checks
  • Inspect door strike pin and handle latch hook for plastic deformation, breakage, or misalignment.
  • Check door hinge alignment: a sagging door prevents the latch tongue from engaging the safety microswitch.
  • Locate and verify emergency manual pull cord inside the lower drain pump hatch.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Candy ER22

FAQ TREE
What does error code ER22 mean on a Candy appliance?

Candy error code ER22 indicates: Candy Moderna / Idea / Smart Touch Induction Cooktop: Touch control evaluation hardware fault ER22; capacitive sensing integrated circuit detects an internal analog front-end failure..

What is the root cause of Candy error code ER22?

The primary root cause for Candy code ER22 is: On Candy cooktops utilizing Moderna & Idea high-frequency induction power generator, electromagnetic pan detection, and capacitive touch interface: Conductive liquid leakage inside the chassis onto touch sensor PCB, broken capacitive spring pin, or static discharge damage..

How do I fix or resolve Candy error code ER22?

To resolve error code ER22: Open hob housing. Inspect touch sensor PCB for liquid stains or corrosion. Clean contacts with isopropyl alcohol. Replace touch PCB if hardware damaged. Wipe glass surface completely dry, power down circuit breaker for 60 seconds, restore supply and touch Key Lock for 5 seconds.

Is it safe to clear Candy error code ER22 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Candy code ER22 persists, the physical component causing On Candy cooktops utilizing Moderna & Idea high-frequency induction power generator, electromagnetic pan detection, and capacitive touch interface: Conductive liquid leakage inside the chassis onto touch sensor PCB, broken capacitive spring pin, or static discharge damage. must be inspected or replaced.

How do I test electrical resistance for Candy code ER22 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts across Across PTC heater terminals on lock bezel; switch contact reads <0.2Ω when locked. Expected nominal reading is 800Ω–1.5kΩ (PTC terminals L-N) / 60Ω–120Ω (Pulse Solenoid). Tolerance: ±15%. Switch contacts must read open (OL) when unlocked and 0.0Ω–0.2Ω when fully latched..

What safety protocol must be followed before servicing Candy code ER22?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

What does Candy error code ER22 mean on a Hob?

Candy error code ER22 on a Hob indicates: Candy Moderna / Idea / Smart Touch Induction Cooktop: Touch control evaluation hardware fault ER22; capacitive sensing integrated circuit detects an internal analog front-end failure.. Primary cause: On Candy cooktops utilizing Moderna & Idea high-frequency induction power generator, electromagnetic pan detection, and capacitive touch interface: Conductive liquid leakage inside the chassis onto touch sensor PCB, broken capacitive spring pin, or static discharge damage.. Recommended solution: Open hob housing. Inspect touch sensor PCB for liquid stains or corrosion. Clean contacts with isopropyl alcohol. Replace touch PCB if hardware damaged. Wipe glass surface completely dry, power down circuit breaker for 60 seconds, restore supply and touch Key Lock for 5 seconds..

What does Candy error code ER22 mean on a Oven?

Candy error code ER22 on a Oven indicates: Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Touch control panel matrix evaluation error Er22; touch controller detects invalid internal scanning line pattern.. Primary cause: On Candy ovens featuring Timeless & Moderna precision convection thermal management, tangential cooling ventilation, and GIAS electronic programmer: Moisture condensation between glass panel and touch PCB, mechanical displacement of touch springs, or controller IC defect.. Recommended solution: Dismantle fascia panel and clean/dry glass inner surface. Ensure all conductive spring contacts sit centered on designated capacitive pad zones. Turn programmer knob to Off, disconnect mains power at the isolation breaker for 60 seconds, restore power and set the electronic timer clock..

Community Verification

COMMUNITY

Did this solution resolve the issue?

Candy ER22 — Multi-Appliance Technical Reference

Verified OEM diagnostic specifications across all appliance systems sharing this fault code.

Candy ER22 — Hob

[ACTIVE]
Symptom / Description:

Candy Moderna / Idea / Smart Touch Induction Cooktop: Touch control evaluation hardware fault ER22; capacitive sensing integrated circuit detects an internal analog front-end failure.

Root Cause:

On Candy cooktops utilizing Moderna & Idea high-frequency induction power generator, electromagnetic pan detection, and capacitive touch interface: Conductive liquid leakage inside the chassis onto touch sensor PCB, broken capacitive spring pin, or static discharge damage.

Repair Instructions:

Open hob housing. Inspect touch sensor PCB for liquid stains or corrosion. Clean contacts with isopropyl alcohol. Replace touch PCB if hardware damaged. Wipe glass surface completely dry, power down circuit breaker for 60 seconds, restore supply and touch Key Lock for 5 seconds.

Candy ER22 — Oven

Symptom / Description:

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Touch control panel matrix evaluation error Er22; touch controller detects invalid internal scanning line pattern.

Root Cause:

On Candy ovens featuring Timeless & Moderna precision convection thermal management, tangential cooling ventilation, and GIAS electronic programmer: Moisture condensation between glass panel and touch PCB, mechanical displacement of touch springs, or controller IC defect.

Repair Instructions:

Dismantle fascia panel and clean/dry glass inner surface. Ensure all conductive spring contacts sit centered on designated capacitive pad zones. Turn programmer knob to Off, disconnect mains power at the isolation breaker for 60 seconds, restore power and set the electronic timer clock.

SEMANTIC KNOWLEDGE GRAPH // CANDY

Related Candy Hob / Cooktop Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

ER31Hob
Door Lock Mechanism & Safety Interlock
Candy Moderna / Idea / Smart Touch Induction Cooktop: Power board configuration data corrupt...
Inspect Protocol
ER36Hob
NTC Temperature Sensor & Thermistor
Candy Moderna / Idea / Smart Touch Induction Cooktop: Touch board ambient NTC sensor shorted...
Inspect Protocol
ER47Hob
Drive Motor, Inverter & Tachometer Sensor
Candy Moderna / Idea / Smart Touch Induction Cooktop: LIN-Bus communication between touch co...
Inspect Protocol
F0Hob
NTC Temperature Sensor & Thermistor
Candy Moderna / Idea / Smart Touch Induction Cooktop: Cooking coil temperature sensor discon...
Inspect Protocol
F1Hob
NTC Temperature Sensor & Thermistor
Candy Moderna / Idea / Smart Touch Induction Cooktop: Cooking coil temperature sensor short ...
Inspect Protocol
F2Hob
Drive Motor, Inverter & Tachometer Sensor
Candy Moderna / Idea / Smart Touch Induction Cooktop: Communication loss to induction genera...
Inspect Protocol
F7Hob
Drive Motor, Inverter & Tachometer Sensor
Candy Moderna / Idea / Smart Touch Induction Cooktop: Mains supply frequency out of limits F...
Inspect Protocol
F8Hob
Door Lock Mechanism & Safety Interlock
Candy Moderna / Idea / Smart Touch Induction Cooktop: Continuous heating safety timer shutof...
Inspect Protocol
F9Hob
Heating Element, Thermostat & Safety Fuse
Candy Moderna / Idea / Smart Touch Induction Cooktop: Induction coil current sensor calibrat...
Inspect Protocol
LHob
Door Lock Mechanism & Safety Interlock
Candy Induction Hob touch panel shows 'L' on all zone displays and control keys do not respo...
Inspect Protocol
UHob
Door Lock Mechanism & Safety Interlock
Candy Moderna / Idea / Smart Touch Induction Cooktop: Mains supply undervoltage / phase miss...
Inspect Protocol
E0Hob
Door Lock Mechanism & Safety Interlock
Candy Moderna / Idea / Smart Touch Induction Cooktop: Touch control module initialization er...
Inspect Protocol
E1Hob
Water Level Pressure Switch & Air Dome
Candy Moderna / Idea / Smart Touch Induction Cooktop: Touch sensor zone covered by object or...
Inspect Protocol
E2Hob
NTC Temperature Sensor & Thermistor
Candy Moderna / Idea / Smart Touch Induction Cooktop: Induction cooking zone coil overheat E...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy