Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEF6
Candy
Candy // OFFICIAL DIAGNOSTIC BENCH

Candy Tumble Dryer F6

DryerDrive Motor, Inverter & Tachometer Sensor
High-efficiency heat pump tumble dryer with ergonomic titanium drum and digital sensor display
Dryer
Select Appliance Type
0ms Instant Telemetry Switch
Haier / Candy / Hoover / GE Group: Equivalent Code Across OEM Group Brands
Haier Europe / Candy-Hoover Shared Electronic Platform
HaierF6HooverF6RosièresF6ZerowattF6IbernaF6GEF6
Other Brands Sharing Code F6:BoschF6MieleF6SiemensF6LGF6WhirlpoolF6ElectroluxF6AEGF6IndesitF6BauknechtF6

Symptom / Description

FAULT

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Auxiliary heat-pump cooling fan fault F6; compressor compartment ventilation fan motor stalled or disconnected.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Candy dryers utilizing RapidÓ heat-pump thermodynamic circuit, 7-sensor electronic moisture tracking, and hOn remote diagnostics: Foreign object or fluff obstructing fan blades, open fan motor winding (~200–500 Ω), or failed drive circuit.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Inspect cooling fan in lower compressor bay. Ensure fan blade spins freely without rubbing. Measure fan motor coil resistance (~200–500 Ω). Switch selector to Off, press and hold Start and Delay Start together for 5 seconds until buzzer beeps twice, then turn to 12 o'clock.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Candy Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Drive Motor, Inverter & Tachometer Loop

3-Phase BLDC Stator U-V-W, Inverter IPM Module & Tachometer G1

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III8.2 Ω (U-V)VΩCOM3-PHASE BLDC MOTOR M1ROTORUVWTACHO G1 (60-120Ω)
Target Component
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Nominal Resistance / Test Range
3Ω–6Ω (BLDC phase U-V-W) / 60Ω–180Ω (Tacho coil) / 1.5Ω–3.5Ω (Universal stator)
Test Harness Pins
Across phase pins U-V, V-W, U-W on motor harness; across tacho pins
Diagnostic Verification Rule
Unbalanced phase winding resistance indicates burned stator. OL on tachometer causes instant drum shutdown.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDrive Motor, Inverter & Tachometer SensorTumble Dryer
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
3Ω–6Ω (BLDC phase U-V-W) / 60Ω–180Ω (Tacho coil) / 1.5Ω–3.5Ω (Universal stator)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Test Pins & Connections
PROBE (+)
PROBE (-)
Across phase pins U-V, V-W, U-W on motor harness; across tacho pins
Tolerance & Diagnostic CriteriaBLDC phase winding values must be strictly balanced within ±0.3Ω. Hand rotation generates 1V–4V AC on tacho.
1. Pre-Intervention Electrical Safety Protocols
  • !High-Voltage Safety Protocol & DC Bus: Wait at least 5 minutes after power cutoff to allow inverter DC bus capacitors (380V DC) to bleed down.
  • !Verify 0V DC across inverter filter capacitors before unplugging motor harness connectors.
  • !Keep hands clear of drive belt and pulleys during any manual rotation tng.
3. Preliminary Mechanical & Visual Checks
  • Slip off drive belt and spin drum/motor shaft by hand to check for roaring or seized ball bearings.
  • For universal motors: verify carbon brushes have at least 10mm remaining length and smooth contact faces.
  • Inspect motor suspension rubber mounts and drive belt tension/groove profile.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Candy F6

FAQ TREE
What does error code F6 mean on a Candy appliance?

Candy error code F6 indicates: Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Auxiliary heat-pump cooling fan fault F6; compressor compartment ventilation fan motor stalled or disconnected..

What is the root cause of Candy error code F6?

The primary root cause for Candy code F6 is: On Candy dryers utilizing RapidÓ heat-pump thermodynamic circuit, 7-sensor electronic moisture tracking, and hOn remote diagnostics: Foreign object or fluff obstructing fan blades, open fan motor winding (~200–500 Ω), or failed drive circuit..

How do I fix or resolve Candy error code F6?

To resolve error code F6: Inspect cooling fan in lower compressor bay. Ensure fan blade spins freely without rubbing. Measure fan motor coil resistance (~200–500 Ω). Switch selector to Off, press and hold Start and Delay Start together for 5 seconds until buzzer beeps twice, then turn to 12 o'clock.

Is it safe to clear Candy error code F6 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Candy code F6 persists, the physical component causing On Candy dryers utilizing RapidÓ heat-pump thermodynamic circuit, 7-sensor electronic moisture tracking, and hOn remote diagnostics: Foreign object or fluff obstructing fan blades, open fan motor winding (~200–500 Ω), or failed drive circuit. must be inspected or replaced.

How do I test electrical resistance for Candy code F6 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test 3-Phase Motor Windings / Tacho Generator / Carbon Brushes across Across phase pins U-V, V-W, U-W on motor harness; across tacho pins. Expected nominal reading is 3Ω–6Ω (BLDC phase U-V-W) / 60Ω–180Ω (Tacho coil) / 1.5Ω–3.5Ω (Universal stator). Tolerance: BLDC phase winding values must be strictly balanced within ±0.3Ω. Hand rotation generates 1V–4V AC on tacho..

What safety protocol must be followed before servicing Candy code F6?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

What does Candy error code F6 mean on a Tumble Dryer?

Candy error code F6 on a Tumble Dryer indicates: Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Auxiliary heat-pump cooling fan fault F6; compressor compartment ventilation fan motor stalled or disconnected.. Primary cause: On Candy dryers utilizing RapidÓ heat-pump thermodynamic circuit, 7-sensor electronic moisture tracking, and hOn remote diagnostics: Foreign object or fluff obstructing fan blades, open fan motor winding (~200–500 Ω), or failed drive circuit.. Recommended solution: Inspect cooling fan in lower compressor bay. Ensure fan blade spins freely without rubbing. Measure fan motor coil resistance (~200–500 Ω). Switch selector to Off, press and hold Start and Delay Start together for 5 seconds until buzzer beeps twice, then turn to 12 o'clock..

What does Candy error code F6 mean on a Refrigerator / Freezer?

Candy error code F6 on a Refrigerator / Freezer indicates: Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Refrigerant switching valve error F6; bistable 3-way solenoid valve fails to direct refrigerant between fridge and freezer circuits.. Primary cause: On Candy refrigeration units featuring Fresco Total No-Frost dual-circulation cooling, multi-sensor temperature regulation, and inverter compressor: Open bistable solenoid coil, debris stuck in valve seat, or missing directional driving pulse from main PCB.. Recommended solution: Measure bistable valve coil resistance (nominal ~1.5 kΩ to 2.5 kΩ). Check for DC steering pulse during dual cooling demand. Replace valve assembly if coil open. Reset: Press and hold Temp Set and Super Cool buttons together for 8 seconds until the display chime signals memory clear, then release..

Community Verification

COMMUNITY

Did this solution resolve the issue?

Candy F6 — Multi-Appliance Technical Reference

Verified OEM diagnostic specifications across all appliance systems sharing this fault code.

Candy F6 — Dryer

[ACTIVE]
Symptom / Description:

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Auxiliary heat-pump cooling fan fault F6; compressor compartment ventilation fan motor stalled or disconnected.

Root Cause:

On Candy dryers utilizing RapidÓ heat-pump thermodynamic circuit, 7-sensor electronic moisture tracking, and hOn remote diagnostics: Foreign object or fluff obstructing fan blades, open fan motor winding (~200–500 Ω), or failed drive circuit.

Repair Instructions:

Inspect cooling fan in lower compressor bay. Ensure fan blade spins freely without rubbing. Measure fan motor coil resistance (~200–500 Ω). Switch selector to Off, press and hold Start and Delay Start together for 5 seconds until buzzer beeps twice, then turn to 12 o'clock.

Candy F6 — Refrigerator / Freezer

Symptom / Description:

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Refrigerant switching valve error F6; bistable 3-way solenoid valve fails to direct refrigerant between fridge and freezer circuits.

Root Cause:

On Candy refrigeration units featuring Fresco Total No-Frost dual-circulation cooling, multi-sensor temperature regulation, and inverter compressor: Open bistable solenoid coil, debris stuck in valve seat, or missing directional driving pulse from main PCB.

Repair Instructions:

Measure bistable valve coil resistance (nominal ~1.5 kΩ to 2.5 kΩ). Check for DC steering pulse during dual cooling demand. Replace valve assembly if coil open. Reset: Press and hold Temp Set and Super Cool buttons together for 8 seconds until the display chime signals memory clear, then release.

SEMANTIC KNOWLEDGE GRAPH // CANDY

Related Candy Tumble Dryer Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E01Tumble Dryer
Heating Element, Thermostat & Safety Fuse
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Airflow restriction warning E01; door ...
Inspect Protocol
E02Tumble Dryer
NTC Temperature Sensor & Thermistor
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Process air duct NTC sensor error E02;...
Inspect Protocol
E03Tumble Dryer
General System & Mechanical Integration
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Maximum drying cycle time exceeded E03...
Inspect Protocol
E04Tumble Dryer
Heating Element, Thermostat & Safety Fuse
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Heating circuit safety lockout E04; he...
Inspect Protocol
E05Tumble Dryer
NTC Temperature Sensor & Thermistor
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Heat pump compressor thermistor fault ...
Inspect Protocol
E06Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Drum motor drive failure E06; motor hu...
Inspect Protocol
E07Tumble Dryer
Drainage System & Drain Pump
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Drum rotation sensor speed feedback mi...
Inspect Protocol
E08Tumble Dryer
Heating Element, Thermostat & Safety Fuse
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Rear heater safety Klixon thermostat o...
Inspect Protocol
E09Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Drum motor drive semiconductor failure...
Inspect Protocol
E10Tumble Dryer
Door Lock Mechanism & Safety Interlock
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Moisture sensing conductivity circuit ...
Inspect Protocol
E11Tumble Dryer
Drainage System & Drain Pump
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Exhaust air temperature overheat E11; ...
Inspect Protocol
E12Tumble Dryer
Electronic Control Board (PCB) & Bus Communications
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Serial communication timeout E12; disp...
Inspect Protocol
E13Tumble Dryer
General System & Mechanical Integration
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Condensate collection container full a...
Inspect Protocol
E14Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor
Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Condensate lift pump motor fault E14; ...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy