Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEF7
Candy
Candy // OFFICIAL DIAGNOSTIC BENCH

Candy Hob F7

HobDrive Motor, Inverter & Tachometer Sensor
Integrated luxury convection oven and induction cooktop with illuminated touch controls
Hob
Select Appliance Type
0ms Instant Telemetry Switch
Haier / Candy / Hoover / GE Group: Equivalent Code Across OEM Group Brands
Haier Europe / Candy-Hoover Shared Electronic Platform
HaierF7HooverF7RosièresF7ZerowattF7IbernaF7GEF7
Other Brands Sharing Code F7:BoschF7MieleF7SiemensF7LGF7WhirlpoolF7ElectroluxF7AEGF7IndesitF7BauknechtF7

Symptom / Description

FAULT

Candy Moderna / Idea / Smart Touch Induction Cooktop: Mains supply frequency out of limits F7; AC power line frequency falls outside 47 Hz–63 Hz operating window.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Candy cooktops utilizing Moderna & Idea high-frequency induction power generator, electromagnetic pan detection, and capacitive touch interface: Unstable generator or solar inverter power supply, severe grid harmonic distortion, or failed zero-crossing detection circuit on board.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Measure AC line frequency with digital multimeter (must read 50.0 Hz or 60.0 Hz ±1 Hz). If running on generator, adjust governor. Replace filter board if grid is normal. Wipe glass surface completely dry, power down circuit breaker for 60 seconds, restore supply and touch Key Lock for 5 seconds.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Candy Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Drive Motor, Inverter & Tachometer Loop

3-Phase BLDC Stator U-V-W, Inverter IPM Module & Tachometer G1

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III8.2 Ω (U-V)VΩCOM3-PHASE BLDC MOTOR M1ROTORUVWTACHO G1 (60-120Ω)
Target Component
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Nominal Resistance / Test Range
3Ω–6Ω (BLDC phase U-V-W) / 60Ω–180Ω (Tacho coil) / 1.5Ω–3.5Ω (Universal stator)
Test Harness Pins
Across phase pins U-V, V-W, U-W on motor harness; across tacho pins
Diagnostic Verification Rule
Unbalanced phase winding resistance indicates burned stator. OL on tachometer causes instant drum shutdown.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDrive Motor, Inverter & Tachometer SensorHob / Cooktop
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
3Ω–6Ω (BLDC phase U-V-W) / 60Ω–180Ω (Tacho coil) / 1.5Ω–3.5Ω (Universal stator)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Test Pins & Connections
PROBE (+)
PROBE (-)
Across phase pins U-V, V-W, U-W on motor harness; across tacho pins
Tolerance & Diagnostic CriteriaBLDC phase winding values must be strictly balanced within ±0.3Ω. Hand rotation generates 1V–4V AC on tacho.
1. Pre-Intervention Electrical Safety Protocols
  • !High-Voltage Safety Protocol & DC Bus: Wait at least 5 minutes after power cutoff to allow inverter DC bus capacitors (380V DC) to bleed down.
  • !Verify 0V DC across inverter filter capacitors before unplugging motor harness connectors.
  • !Keep hands clear of drive belt and pulleys during any manual rotation tng.
3. Preliminary Mechanical & Visual Checks
  • Slip off drive belt and spin drum/motor shaft by hand to check for roaring or seized ball bearings.
  • For universal motors: verify carbon brushes have at least 10mm remaining length and smooth contact faces.
  • Inspect motor suspension rubber mounts and drive belt tension/groove profile.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Candy F7

FAQ TREE
What does error code F7 mean on a Candy appliance?

Candy error code F7 indicates: Candy Moderna / Idea / Smart Touch Induction Cooktop: Mains supply frequency out of limits F7; AC power line frequency falls outside 47 Hz–63 Hz operating window..

What is the root cause of Candy error code F7?

The primary root cause for Candy code F7 is: On Candy cooktops utilizing Moderna & Idea high-frequency induction power generator, electromagnetic pan detection, and capacitive touch interface: Unstable generator or solar inverter power supply, severe grid harmonic distortion, or failed zero-crossing detection circuit on board..

How do I fix or resolve Candy error code F7?

To resolve error code F7: Measure AC line frequency with digital multimeter (must read 50.0 Hz or 60.0 Hz ±1 Hz). If running on generator, adjust governor. Replace filter board if grid is normal. Wipe glass surface completely dry, power down circuit breaker for 60 seconds, restore supply and touch Key Lock for 5 seconds.

Is it safe to clear Candy error code F7 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Candy code F7 persists, the physical component causing On Candy cooktops utilizing Moderna & Idea high-frequency induction power generator, electromagnetic pan detection, and capacitive touch interface: Unstable generator or solar inverter power supply, severe grid harmonic distortion, or failed zero-crossing detection circuit on board. must be inspected or replaced.

How do I test electrical resistance for Candy code F7 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test 3-Phase Motor Windings / Tacho Generator / Carbon Brushes across Across phase pins U-V, V-W, U-W on motor harness; across tacho pins. Expected nominal reading is 3Ω–6Ω (BLDC phase U-V-W) / 60Ω–180Ω (Tacho coil) / 1.5Ω–3.5Ω (Universal stator). Tolerance: BLDC phase winding values must be strictly balanced within ±0.3Ω. Hand rotation generates 1V–4V AC on tacho..

What safety protocol must be followed before servicing Candy code F7?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

What does Candy error code F7 mean on a Hob?

Candy error code F7 on a Hob indicates: Candy Moderna / Idea / Smart Touch Induction Cooktop: Mains supply frequency out of limits F7; AC power line frequency falls outside 47 Hz–63 Hz operating window.. Primary cause: On Candy cooktops utilizing Moderna & Idea high-frequency induction power generator, electromagnetic pan detection, and capacitive touch interface: Unstable generator or solar inverter power supply, severe grid harmonic distortion, or failed zero-crossing detection circuit on board.. Recommended solution: Measure AC line frequency with digital multimeter (must read 50.0 Hz or 60.0 Hz ±1 Hz). If running on generator, adjust governor. Replace filter board if grid is normal. Wipe glass surface completely dry, power down circuit breaker for 60 seconds, restore supply and touch Key Lock for 5 seconds..

What does Candy error code F7 mean on a Oven?

Candy error code F7 on a Oven indicates: Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Stuck touch key / keypad matrix line shorted F7; button input is registered as permanently pressed.. Primary cause: On Candy ovens utilizing Timeless & Moderna precision convection thermal management, tangential cooling ventilation, and GIAS electronic programmer: Liquid spill on control glass, conductive residue between touch electrodes, or shorted membrane switch line.. Recommended solution: Clean and dry control console thoroughly. If touch buttons remain unresponsive or code persists, replace touch keypad or console board. Turn programmer knob to Off, disconnect mains power at the isolation breaker for 60 seconds, restore power and set the electronic timer clock..

What does Candy error code F7 mean on a Washing Machine?

Candy error code F7 on a Washing Machine indicates: Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Motor drive board communication / synchronization fault F7; inverter driver board fails to command motor rotation.. Primary cause: On Candy washers utilizing Speed-Drive Inverter brushless motor, Smart Touch NFC / hOn Wi-Fi connectivity, and GIAS Cuore electronic platform: Blown motor driver fuse on inverter board, damaged gate driver IC, or lost serial communication between display and drive board.. Recommended solution: Inspect wiring harness connecting main PCB and motor drive board. Verify DC bus voltage on driver capacitors (~310V–340V DC). Replace driver board if damaged. Turn dial to Off, press and hold Start/Pause and Extra Rinse simultaneously for 5 seconds until display flashes '888', then power cycle..

Community Verification

COMMUNITY

Did this solution resolve the issue?

Candy F7 — Multi-Appliance Technical Reference

Verified OEM diagnostic specifications across all appliance systems sharing this fault code.

Candy F7 — Hob

[ACTIVE]
Symptom / Description:

Candy Moderna / Idea / Smart Touch Induction Cooktop: Mains supply frequency out of limits F7; AC power line frequency falls outside 47 Hz–63 Hz operating window.

Root Cause:

On Candy cooktops utilizing Moderna & Idea high-frequency induction power generator, electromagnetic pan detection, and capacitive touch interface: Unstable generator or solar inverter power supply, severe grid harmonic distortion, or failed zero-crossing detection circuit on board.

Repair Instructions:

Measure AC line frequency with digital multimeter (must read 50.0 Hz or 60.0 Hz ±1 Hz). If running on generator, adjust governor. Replace filter board if grid is normal. Wipe glass surface completely dry, power down circuit breaker for 60 seconds, restore supply and touch Key Lock for 5 seconds.

Candy F7 — Oven

Symptom / Description:

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Stuck touch key / keypad matrix line shorted F7; button input is registered as permanently pressed.

Root Cause:

On Candy ovens utilizing Timeless & Moderna precision convection thermal management, tangential cooling ventilation, and GIAS electronic programmer: Liquid spill on control glass, conductive residue between touch electrodes, or shorted membrane switch line.

Repair Instructions:

Clean and dry control console thoroughly. If touch buttons remain unresponsive or code persists, replace touch keypad or console board. Turn programmer knob to Off, disconnect mains power at the isolation breaker for 60 seconds, restore power and set the electronic timer clock.

Candy F7 — Washing Machine

Symptom / Description:

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Motor drive board communication / synchronization fault F7; inverter driver board fails to command motor rotation.

Root Cause:

On Candy washers utilizing Speed-Drive Inverter brushless motor, Smart Touch NFC / hOn Wi-Fi connectivity, and GIAS Cuore electronic platform: Blown motor driver fuse on inverter board, damaged gate driver IC, or lost serial communication between display and drive board.

Repair Instructions:

Inspect wiring harness connecting main PCB and motor drive board. Verify DC bus voltage on driver capacitors (~310V–340V DC). Replace driver board if damaged. Turn dial to Off, press and hold Start/Pause and Extra Rinse simultaneously for 5 seconds until display flashes '888', then power cycle.

SEMANTIC KNOWLEDGE GRAPH // CANDY

Related Candy Hob / Cooktop Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

F8Hob
Door Lock Mechanism & Safety Interlock
Candy Moderna / Idea / Smart Touch Induction Cooktop: Continuous heating safety timer shutof...
Inspect Protocol
F9Hob
Heating Element, Thermostat & Safety Fuse
Candy Moderna / Idea / Smart Touch Induction Cooktop: Induction coil current sensor calibrat...
Inspect Protocol
LHob
Door Lock Mechanism & Safety Interlock
Candy Induction Hob touch panel shows 'L' on all zone displays and control keys do not respo...
Inspect Protocol
UHob
Door Lock Mechanism & Safety Interlock
Candy Moderna / Idea / Smart Touch Induction Cooktop: Mains supply undervoltage / phase miss...
Inspect Protocol
E0Hob
Door Lock Mechanism & Safety Interlock
Candy Moderna / Idea / Smart Touch Induction Cooktop: Touch control module initialization er...
Inspect Protocol
E1Hob
Water Level Pressure Switch & Air Dome
Candy Moderna / Idea / Smart Touch Induction Cooktop: Touch sensor zone covered by object or...
Inspect Protocol
E2Hob
NTC Temperature Sensor & Thermistor
Candy Moderna / Idea / Smart Touch Induction Cooktop: Induction cooking zone coil overheat E...
Inspect Protocol
E3Hob
Heating Element, Thermostat & Safety Fuse
Candy Moderna / Idea / Smart Touch Induction Cooktop: Induction power board IGBT heatsink ov...
Inspect Protocol
E4Hob
NTC Temperature Sensor & Thermistor
Candy Moderna / Idea / Smart Touch Induction Cooktop: Induction coil temperature sensor circ...
Inspect Protocol
E5Hob
Door Lock Mechanism & Safety Interlock
Candy Moderna / Idea / Smart Touch Induction Cooktop: Mains supply overvoltage fault E5; inp...
Inspect Protocol
E6Hob
Door Lock Mechanism & Safety Interlock
Candy Moderna / Idea / Smart Touch Induction Cooktop: Mains supply undervoltage fault E6; in...
Inspect Protocol
E7Hob
Drive Motor, Inverter & Tachometer Sensor
Candy Moderna / Idea / Smart Touch Induction Cooktop: Cooling fan failure E7; internal induc...
Inspect Protocol
E8Hob
Drive Motor, Inverter & Tachometer Sensor
Candy Moderna / Idea / Smart Touch Induction Cooktop: Pan detection circuit error E8; coil c...
Inspect Protocol
E9Hob
Door Lock Mechanism & Safety Interlock
Candy Moderna / Idea / Smart Touch Induction Cooktop: Internal bus communication failure E9;...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy