Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Castor I23
FAQ TREEWhat does error code I23 mean on a Castor appliance?
Castor error code I23 indicates: Castor CDF Series / Lavastoviglie Silenziosa Dishwasher: Drain pump triac failure or feedback sensing mismatch i23 on main electronic motherboard..
What is the root cause of Castor error code I23?
The primary root cause for Castor code I23 is: On Castor (Castor CDF Series / Lavastoviglie Silenziosa Dishwasher) models: Triac destroyed by short-circuited drain pump stator coil, moisture on pump spade terminals, or open sensing resistor on motherboard..
How do I fix or resolve Castor error code I23?
To resolve error code I23: Measure drain pump coil resistance (must be 160–220 Ω; if < 150 Ω replace pump first!). Inspect PCB for burned triac package. Hold Start and Reset keys for 5 seconds until the display clears the alarm code and restores standby status.
Is it safe to clear Castor error code I23 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Castor code I23 persists, the physical component causing On Castor (Castor CDF Series / Lavastoviglie Silenziosa Dishwasher) models: Triac destroyed by short-circuited drain pump stator coil, moisture on pump spade terminals, or open sensing resistor on motherboard. must be inspected or replaced.
How do I test electrical resistance for Castor code I23 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..
What safety protocol must be followed before servicing Castor code I23?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?



