Electrolux E52 — Dryer
[ACTIVE]Electrolux PerfectCare / GentleCare Heat-Pump Dryer: Motor thermal protector tripped E52; motor halts during high ambient temperature or heavy load operation.
On Electrolux (Electrolux PerfectCare / GentleCare Heat-Pump Dryer) models: Motor internal Klixon thermal switch opened (> 135°C), lint accumulation obstructing cooling blower wheel, seized drum support rollers, or excessive laundry load.
Allow motor to cool for 45 minutes. Vacuum fluff from motor housing and cooling fan. Spin drum by hand to verify roller bearings spin freely without binding. Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.