[ACTIVE]Electrolux PerfectCare / GentleCare Heat-Pump Dryer: Motor jammed or drum blocked E54; motor hums but fails to rotate, or drive belt broken/derailed from pulley.
On Electrolux (Electrolux PerfectCare / GentleCare Heat-Pump Dryer) models: Poly-V drive belt snapped or slipped, motor starting capacitor dried out (0 μF reading), foreign object wedged between drum and seal, or seized motor bearings.
Check drum drive belt and spring-loaded tensioner pulley. Test motor capacitor with multimeter (replace if < 85% rated μF). Verify drum turns smoothly by hand. Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.