Electrolux E58 — Dryer
[ACTIVE]Electrolux PerfectCare / GentleCare Heat-Pump Dryer: Heat pump compressor phase current exceeded E58 (> 4.5A); drive board limits frequency to prevent inverter thermal destruction.
On Electrolux (Electrolux PerfectCare / GentleCare Heat-Pump Dryer) models: Extreme refrigeration circuit load due to saturated air filters, failing compressor capacitor (on non-inverter models) or internal piston friction.
Clean dual lint filters under running water and let dry completely. Vacuum heat exchanger duct. Measure live running current with clamp meter. Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.