[ACTIVE]Electrolux PerfectCare / GentleCare Heat-Pump Dryer: Insufficient heating rate E61; temperature rise inside drum during first 20 minutes is below calibrated threshold.
On Electrolux (Electrolux PerfectCare / GentleCare Heat-Pump Dryer) models: One of two heating elements open (operating at half power), degraded heat pump refrigerant charge (R134a / R290 leak), or severely restricted airflow.