Electrolux E62 — Dryer
[ACTIVE]Electrolux PerfectCare / GentleCare Heat-Pump Dryer: Overheating alarm E62; drum temperature exceeds maximum safety limit (> 95°C) and cycle halts immediately.
On Electrolux (Electrolux PerfectCare / GentleCare Heat-Pump Dryer) models: Stuck closed heating relay contact on PCB (continuous power to heater), blocked lint filter stopping heat dissipation, or defective forward duct NTC sensor.
Inspect heating relay on control board (ensure contacts open when unpowered, resistance ∞ Ω). Clean all lint filters and measure front duct NTC resistance (~5–6 kΩ at 25°C). Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.