Frequently Asked Questions: Faure E42
FAQ TREEWhat does error code E42 mean on a Faure appliance?
Faure error code E42 indicates: Faure FWG / FWF Series / Magic'45 Compact Washer: Door unlocking aperture failure E42; door interlock fails to release latch mechanism after cycle completes..
What is the root cause of Faure error code E42?
The primary root cause for Faure code E42 is: On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: PTC bi-metal strip failed to cool down, mechanical bimetal latch jammed, or instant pulse unlock solenoid coil open circuit (nominal 120–250 Ω)..
How do I fix or resolve Faure error code E42?
To resolve error code E42: Wait 3 minutes for bi-metal to cool. If still locked, use manual emergency release cord located behind drain filter flap. Replace door interlock. Press and hold Départ/Pause and Annulation buttons for 6 seconds until all status indicators flash synchronously and clear fault memory.
Is it safe to clear Faure error code E42 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Faure code E42 persists, the physical component causing On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: PTC bi-metal strip failed to cool down, mechanical bimetal latch jammed, or instant pulse unlock solenoid coil open circuit (nominal 120–250 Ω). must be inspected or replaced.
How do I test electrical resistance for Faure code E42 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..
What safety protocol must be followed before servicing Faure code E42?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.