Gaggenau E27 — Dishwasher
[ACTIVE]Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Mains undervoltage detected E27; AC supply voltage drops below minimum operating threshold (< 190V AC).
On Gaggenau dishwashers: Household electrical grid overloaded by heavy appliances, thin extension cord, loose neutral terminal in socket, or utility power dip.
Plug dishwasher directly into dedicated 16A grounded wall socket (do not use extension cords). Measure AC voltage at outlet (must be 220–240V AC). Press and hold illuminated Start key for 4 seconds until '0:01' abort confirms, close door for final drainage, power off.