Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Gree / Mace EE
FAQ TREEWhat does error code EE mean on a Gree-Mace appliance?
Gree-Mace error code EE indicates: Gree-Mace G10 Inverter / Free Match / GMV5 / GMV6 Multi-VRF Commercial & Residential HVAC: Diagnostic fault code EE registered by the microcomputer controller. Outdoor main control board EEPROM checksum error or memory corruption.
What is the root cause of Gree-Mace error code EE?
The primary root cause for Gree-Mace code EE is: On Gree-Mace appliances engineered with Gree G10 Inverter low-frequency torque control, intelligent dual-stage rotary compressor, 46 Ω electronic expansion valve stepping motor coils, high-voltage PFC boost circuit (380V DC), and precision NTC thermistors (15 kΩ ambient, 20 kΩ coil, 50 kΩ discharge): outdoor main control PCB EEPROM checksum mismatch or memory corruption Metrological tolerance verification: regulated logic power supply 5.0V DC ± 0.1V on outdoor motherboard test pads..
How do I fix or resolve Gree-Mace error code EE?
To resolve error code EE: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: check 5V DC supply rail on power board test points; replace main outdoor PCB if error persists. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Using the remote controller: point at the unit and press 'LIGHT' 6 times in 3 seconds (or hold 'TURBO' + 'MODE' for 5 seconds) to enter diagnostic query mode. For inverter lockout errors (H5, HC, P0, P8, E6), switch off the external electrical isolator / circuit breaker for at least 3 minutes to allow DC bus capacitors to fully discharge.
Is it safe to clear Gree-Mace error code EE by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Gree-Mace code EE persists, the physical component causing On Gree-Mace appliances engineered with Gree G10 Inverter low-frequency torque control, intelligent dual-stage rotary compressor, 46 Ω electronic expansion valve stepping motor coils, high-voltage PFC boost circuit (380V DC), and precision NTC thermistors (15 kΩ ambient, 20 kΩ coil, 50 kΩ discharge): outdoor main control PCB EEPROM checksum mismatch or memory corruption Metrological tolerance verification: regulated logic power supply 5.0V DC ± 0.1V on outdoor motherboard test pads. must be inspected or replaced.
How do I test electrical resistance for Gree-Mace code EE using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..
What safety protocol must be followed before servicing Gree-Mace code EE?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?



