Haier E10 — Dishwasher
[ACTIVE]Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water diverter valve timeout E10; motorized spray arm alternator disc fails to reach requested position microswitch contact.
On Haier dishwashers utilizing I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Jammed ceramic disc in diverter body, open synchronous drive motor winding (~4–9 kΩ), or defective microswitch.
Measure synchronous motor winding resistance (~4–9 kΩ). Verify cam microswitch continuity when actuated. Inspect diverter disc for foreign matter. Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.