Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEE11
Haier
Haier // OFFICIAL DIAGNOSTIC BENCH

Haier Tumble Dryer E11

DryerNTC Temperature Sensor & Thermistor
High-efficiency heat pump tumble dryer with ergonomic titanium drum and digital sensor display
Dryer
Select Appliance Type
0ms Instant Telemetry Switch
Haier / Candy / Hoover / GE Group: Equivalent Code Across OEM Group Brands
Haier Europe / Candy-Hoover Shared Electronic Platform
CandyE11HooverE11RosièresE11ZerowattE11IbernaE11GEE11
Other Brands Sharing Code E11:BoschE11SiemensE11SamsungE11LGE11ElectroluxE11AEGE11BekoE11NeffE11V-ZugE11

Symptom / Description

FAULT

Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Exhaust air temperature overheat E11; air temperature leaving the drum exceeds 80°C triggering thermal protection.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Haier tumble dryers utilizing I-Pro Series Dual Inverter heat-pump circuit, sensor-dry thermistor array, and reverse-tumble motor control: Heavily choked condenser unit, clogged exhaust ductwork, or blocked rear air intake grille behind machine.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Allow appliance to cool for 30 minutes. Remove and wash heat exchanger condenser. Test safety thermostat continuity with a multimeter. Ensure machine has minimum 10 cm rear clearance from wall. Turn dial to Warm Air program, press Dry Level and Time Dry together for 5 seconds until beep sounds, then return to Power Off.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Haier Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Thermal & Heating Loop

Calrod Heating Element R1, Safety Klixon & NTC Thermistor Probe

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III24.6 ΩVΩCOMHEATING ELEMENT R1HEATER R1: 20-28 ΩSAFETY THERMOSTAT (KLIXON)NTC SENSOR (4.8-12kΩ)
Target Component
NTC Temperature Sensor Probe (Thermistor)
Nominal Resistance / Test Range
4.8kΩ–12kΩ (at 20°C–25°C)
Test Harness Pins
Across sensor pins 1-2 (unplugged harness)
Diagnostic Verification Rule
Zero or OL indicates open heating element or tripped safety thermostat. Check insulation to earth.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorTumble Dryer
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Haier E11

FAQ TREE
What does error code E11 mean on a Haier appliance?

Haier error code E11 indicates: Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Exhaust air temperature overheat E11; air temperature leaving the drum exceeds 80°C triggering thermal protection..

What is the root cause of Haier error code E11?

The primary root cause for Haier code E11 is: On Haier tumble dryers utilizing I-Pro Series Dual Inverter heat-pump circuit, sensor-dry thermistor array, and reverse-tumble motor control: Heavily choked condenser unit, clogged exhaust ductwork, or blocked rear air intake grille behind machine..

How do I fix or resolve Haier error code E11?

To resolve error code E11: Allow appliance to cool for 30 minutes. Remove and wash heat exchanger condenser. Test safety thermostat continuity with a multimeter. Ensure machine has minimum 10 cm rear clearance from wall. Turn dial to Warm Air program, press Dry Level and Time Dry together for 5 seconds until beep sounds, then return to Power Off.

Is it safe to clear Haier error code E11 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Haier code E11 persists, the physical component causing On Haier tumble dryers utilizing I-Pro Series Dual Inverter heat-pump circuit, sensor-dry thermistor array, and reverse-tumble motor control: Heavily choked condenser unit, clogged exhaust ductwork, or blocked rear air intake grille behind machine. must be inspected or replaced.

How do I test electrical resistance for Haier code E11 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Haier code E11?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

What does Haier error code E11 mean on a Tumble Dryer?

Haier error code E11 on a Tumble Dryer indicates: Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Exhaust air temperature overheat E11; air temperature leaving the drum exceeds 80°C triggering thermal protection.. Primary cause: On Haier tumble dryers utilizing I-Pro Series Dual Inverter heat-pump circuit, sensor-dry thermistor array, and reverse-tumble motor control: Heavily choked condenser unit, clogged exhaust ductwork, or blocked rear air intake grille behind machine.. Recommended solution: Allow appliance to cool for 30 minutes. Remove and wash heat exchanger condenser. Test safety thermostat continuity with a multimeter. Ensure machine has minimum 10 cm rear clearance from wall. Turn dial to Warm Air program, press Dry Level and Time Dry together for 5 seconds until beep sounds, then return to Power Off..

What does Haier error code E11 mean on a Washing Machine?

Haier error code E11 on a Washing Machine indicates: Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Washer-dryer drying heating fault E11; air heating duct fails to reach temperature or dryer thermistor open circuit.. Primary cause: On Haier washer-dryers with Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Tripped manual reset safety thermostat (Klixon), burned drying heating element (~25–35 Ω), or defective duct NTC (~20 kΩ).. Recommended solution: Check Klixon push-button on top of drying duct. Measure drying element resistance (~25–35 Ω). Test drying duct NTC sensor (~20 kΩ at 25°C). Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off..

Community Verification

COMMUNITY

Did this solution resolve the issue?

Haier E11 — Multi-Appliance Technical Reference

Verified OEM diagnostic specifications across all appliance systems sharing this fault code.

Haier E11 — Dryer

[ACTIVE]
Symptom / Description:

Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Exhaust air temperature overheat E11; air temperature leaving the drum exceeds 80°C triggering thermal protection.

Root Cause:

On Haier tumble dryers utilizing I-Pro Series Dual Inverter heat-pump circuit, sensor-dry thermistor array, and reverse-tumble motor control: Heavily choked condenser unit, clogged exhaust ductwork, or blocked rear air intake grille behind machine.

Repair Instructions:

Allow appliance to cool for 30 minutes. Remove and wash heat exchanger condenser. Test safety thermostat continuity with a multimeter. Ensure machine has minimum 10 cm rear clearance from wall. Turn dial to Warm Air program, press Dry Level and Time Dry together for 5 seconds until beep sounds, then return to Power Off.

Haier E11 — Washing Machine

Symptom / Description:

Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Washer-dryer drying heating fault E11; air heating duct fails to reach temperature or dryer thermistor open circuit.

Root Cause:

On Haier washer-dryers with Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Tripped manual reset safety thermostat (Klixon), burned drying heating element (~25–35 Ω), or defective duct NTC (~20 kΩ).

Repair Instructions:

Check Klixon push-button on top of drying duct. Measure drying element resistance (~25–35 Ω). Test drying duct NTC sensor (~20 kΩ at 25°C). Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.

SEMANTIC KNOWLEDGE GRAPH // HAIER

Related Haier Tumble Dryer Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E12Tumble Dryer
NTC Temperature Sensor & Thermistor
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Serial communication timeout E12; di...
Inspect Protocol
E13Tumble Dryer
NTC Temperature Sensor & Thermistor
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Condensate collection container full...
Inspect Protocol
E14Tumble Dryer
NTC Temperature Sensor & Thermistor
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Condensate lift pump motor fault E14...
Inspect Protocol
E15Tumble Dryer
NTC Temperature Sensor & Thermistor
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Inverter compressor driver fault E15...
Inspect Protocol
E16Tumble Dryer
NTC Temperature Sensor & Thermistor
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Heat pump evaporator coil freezing a...
Inspect Protocol
E17Tumble Dryer
NTC Temperature Sensor & Thermistor
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Drum drive belt breakage detected E1...
Inspect Protocol
E18Tumble Dryer
NTC Temperature Sensor & Thermistor
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Power supply voltage or frequency fa...
Inspect Protocol
E21Tumble Dryer
NTC Temperature Sensor & Thermistor
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Moisture sensing calibration amplifi...
Inspect Protocol
F1Tumble Dryer
NTC Temperature Sensor & Thermistor
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Air intake temperature sensor fault ...
Inspect Protocol
F2Tumble Dryer
NTC Temperature Sensor & Thermistor
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Rear exhaust temperature sensor faul...
Inspect Protocol
F3Tumble Dryer
NTC Temperature Sensor & Thermistor
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Compressor discharge pipe high-tempe...
Inspect Protocol
F4Tumble Dryer
NTC Temperature Sensor & Thermistor
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Condensate evacuation pump failure F...
Inspect Protocol
F5Tumble Dryer
NTC Temperature Sensor & Thermistor
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Motor / compressor inverter communic...
Inspect Protocol
F6Tumble Dryer
NTC Temperature Sensor & Thermistor
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Auxiliary heat-pump cooling fan faul...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy