Haier E11 — Dryer
[ACTIVE]Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Exhaust air temperature overheat E11; air temperature leaving the drum exceeds 80°C triggering thermal protection.
On Haier tumble dryers utilizing I-Pro Series Dual Inverter heat-pump circuit, sensor-dry thermistor array, and reverse-tumble motor control: Heavily choked condenser unit, clogged exhaust ductwork, or blocked rear air intake grille behind machine.
Allow appliance to cool for 30 minutes. Remove and wash heat exchanger condenser. Test safety thermostat continuity with a multimeter. Ensure machine has minimum 10 cm rear clearance from wall. Turn dial to Warm Air program, press Dry Level and Time Dry together for 5 seconds until beep sounds, then return to Power Off.