Haier F7 — Hob
[ACTIVE]Haier I-Move Series / Multi Switch Precision Induction Hob: Mains supply frequency out of limits F7; AC power line frequency falls outside 47 Hz–63 Hz operating window.
On Haier cooktops utilizing I-Move Series / Multi Switch induction power board, high-frequency coil induction, and capacitive sensor glass interface: Unstable generator or solar inverter power supply, severe grid harmonic distortion, or failed zero-crossing detection circuit on board.