Hoover E06 — Dishwasher
[ACTIVE]Hoover H-DISH 300 / 500 / 700 Maxi Tub Smart Dishwasher: Main control board EEPROM verification fault E06; checksum register error halts cycle initialization.
On Hoover dishwashers featuring H-DISH Maxi Tub architecture, Triple Self-Cleaning micro-filtration wash system, and hOn Wi-Fi connectivity: Mains voltage surge damage to microcomputer memory cells, power supply capacitor failure, or unprogrammed module.
Perform hard power reset for 10 minutes. If error returns, access service menu to enter model programming code or install pre-configured PCB. Hold the Programme selector button and Start/Pause together for 6 seconds until all indicator LEDs light up, then power off.