Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEE11
Hoover
Hoover // OFFICIAL DIAGNOSTIC BENCH

Hoover Tumble Dryer E11

DryerDrainage System & Drain Pump
High-efficiency heat pump tumble dryer with ergonomic titanium drum and digital sensor display
Dryer
Select Appliance Type
0ms Instant Telemetry Switch
Haier / Candy / Hoover / GE Group: Equivalent Code Across OEM Group Brands
Haier Europe / Candy-Hoover Shared Electronic Platform
HaierE11CandyE11RosièresE11ZerowattE11IbernaE11GEE11
Other Brands Sharing Code E11:BoschE11SiemensE11SamsungE11LGE11ElectroluxE11AEGE11BekoE11NeffE11

Symptom / Description

FAULT

Hoover H-DRY 300 / 500 Heat-Pump & Auto Care Tumble Dryer: Exhaust air temperature overheat E11; air temperature leaving the drum exceeds 80°C triggering thermal protection.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Hoover tumble dryers utilizing H-DRY Auto Care thermodynamic heat-pump circuit, active conductivity sensor bars, and Eco-Power compressor control: Heavily choked condenser unit, clogged exhaust ductwork, or blocked rear air intake grille behind machine.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Allow appliance to cool for 30 minutes. Remove and wash heat exchanger condenser. Test safety thermostat continuity with a multimeter. Ensure machine has minimum 10 cm rear clearance from wall. Turn cycle knob to 0, hold Start/Pause and Anti-Crease buttons for 6 seconds until buzzer beeps three times, then switch to Off.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Hoover Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Hydraulic & Drainage Loop

Drain Pump M2, Impeller Chamber, Sump Filter & Analog Pressostat

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III168.4 ΩVΩCOMDRAIN PUMP M2DRAIN OUTFLOWRATED COIL: 150-280Ω
Target Component
Drain Pump Motor Stator Coils
Nominal Resistance / Test Range
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)
Test Harness Pins
Across pump motor spade terminals (L-N unclipped)
Diagnostic Verification Rule
Measure coil resistance unplugged. If OL (open loop) or < 50 Ω (shorted), replace pump assembly.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDrainage System & Drain PumpTumble Dryer
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Drain Pump Motor Stator Coils
Test Pins & Connections
PROBE (+)
PROBE (-)
Across pump motor spade terminals (L-N unclipped)
Tolerance & Diagnostic Criteria±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Isolate 230V mains power before accessing the lower pump housing.
  • !Prepare a shallow basin and absorption towels: expect 3 to 10 liters of stagnant trapped water upon filter opening.
  • !Beware of sharp foreign objects (broken glass, needles, screws) trapped inside the impeller cavity.
3. Preliminary Mechanical & Visual Checks
  • Unscrew coin trap filter and clear all foreign debris (coins, hairpins, bra underwires).
  • Rotate pump impeller manually: synchronous magnetic rotors should snap cleanly in 90° intervals without jamming.
  • Check drain hose for kinks, blockages, or unpunched sink spigots; verify drain height is between 65cm and 100cm.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Hoover E11

FAQ TREE
What does error code E11 mean on a Hoover appliance?

Hoover error code E11 indicates: Hoover H-DRY 300 / 500 Heat-Pump & Auto Care Tumble Dryer: Exhaust air temperature overheat E11; air temperature leaving the drum exceeds 80°C triggering thermal protection..

What is the root cause of Hoover error code E11?

The primary root cause for Hoover code E11 is: On Hoover tumble dryers utilizing H-DRY Auto Care thermodynamic heat-pump circuit, active conductivity sensor bars, and Eco-Power compressor control: Heavily choked condenser unit, clogged exhaust ductwork, or blocked rear air intake grille behind machine..

How do I fix or resolve Hoover error code E11?

To resolve error code E11: Allow appliance to cool for 30 minutes. Remove and wash heat exchanger condenser. Test safety thermostat continuity with a multimeter. Ensure machine has minimum 10 cm rear clearance from wall. Turn cycle knob to 0, hold Start/Pause and Anti-Crease buttons for 6 seconds until buzzer beeps three times, then switch to Off.

Is it safe to clear Hoover error code E11 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Hoover code E11 persists, the physical component causing On Hoover tumble dryers utilizing H-DRY Auto Care thermodynamic heat-pump circuit, active conductivity sensor bars, and Eco-Power compressor control: Heavily choked condenser unit, clogged exhaust ductwork, or blocked rear air intake grille behind machine. must be inspected or replaced.

How do I test electrical resistance for Hoover code E11 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..

What safety protocol must be followed before servicing Hoover code E11?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

What does Hoover error code E11 mean on a Tumble Dryer?

Hoover error code E11 on a Tumble Dryer indicates: Hoover H-DRY 300 / 500 Heat-Pump & Auto Care Tumble Dryer: Exhaust air temperature overheat E11; air temperature leaving the drum exceeds 80°C triggering thermal protection.. Primary cause: On Hoover tumble dryers utilizing H-DRY Auto Care thermodynamic heat-pump circuit, active conductivity sensor bars, and Eco-Power compressor control: Heavily choked condenser unit, clogged exhaust ductwork, or blocked rear air intake grille behind machine.. Recommended solution: Allow appliance to cool for 30 minutes. Remove and wash heat exchanger condenser. Test safety thermostat continuity with a multimeter. Ensure machine has minimum 10 cm rear clearance from wall. Turn cycle knob to 0, hold Start/Pause and Anti-Crease buttons for 6 seconds until buzzer beeps three times, then switch to Off..

What does Hoover error code E11 mean on a Washing Machine?

Hoover error code E11 on a Washing Machine indicates: Hoover H-WASH 300 / 500 / 700 Eco-Power Inverter Washer: Washer-dryer drying heating fault E11; air heating duct fails to reach temperature or dryer thermistor open circuit.. Primary cause: On Hoover washer-dryers with Eco-Power permanent magnet brushless motor, Power Care System premix injection, and hOn AI intelligence: Tripped manual reset safety thermostat (Klixon), burned drying heating element (~25–35 Ω), or defective duct NTC (~20 kΩ).. Recommended solution: Check Klixon push-button on top of drying duct. Measure drying element resistance (~25–35 Ω). Test drying duct NTC sensor (~20 kΩ at 25°C). Rotate dial to Off, hold down Start/Pause and Spin Speed keys for 6 seconds until 'rES' appears on the digital readout, then power cycle..

Community Verification

COMMUNITY

Did this solution resolve the issue?

Hoover E11 — Multi-Appliance Technical Reference

Verified OEM diagnostic specifications across all appliance systems sharing this fault code.

Hoover E11 — Dryer

[ACTIVE]
Symptom / Description:

Hoover H-DRY 300 / 500 Heat-Pump & Auto Care Tumble Dryer: Exhaust air temperature overheat E11; air temperature leaving the drum exceeds 80°C triggering thermal protection.

Root Cause:

On Hoover tumble dryers utilizing H-DRY Auto Care thermodynamic heat-pump circuit, active conductivity sensor bars, and Eco-Power compressor control: Heavily choked condenser unit, clogged exhaust ductwork, or blocked rear air intake grille behind machine.

Repair Instructions:

Allow appliance to cool for 30 minutes. Remove and wash heat exchanger condenser. Test safety thermostat continuity with a multimeter. Ensure machine has minimum 10 cm rear clearance from wall. Turn cycle knob to 0, hold Start/Pause and Anti-Crease buttons for 6 seconds until buzzer beeps three times, then switch to Off.

Hoover E11 — Washing Machine

Symptom / Description:

Hoover H-WASH 300 / 500 / 700 Eco-Power Inverter Washer: Washer-dryer drying heating fault E11; air heating duct fails to reach temperature or dryer thermistor open circuit.

Root Cause:

On Hoover washer-dryers with Eco-Power permanent magnet brushless motor, Power Care System premix injection, and hOn AI intelligence: Tripped manual reset safety thermostat (Klixon), burned drying heating element (~25–35 Ω), or defective duct NTC (~20 kΩ).

Repair Instructions:

Check Klixon push-button on top of drying duct. Measure drying element resistance (~25–35 Ω). Test drying duct NTC sensor (~20 kΩ at 25°C). Rotate dial to Off, hold down Start/Pause and Spin Speed keys for 6 seconds until 'rES' appears on the digital readout, then power cycle.

SEMANTIC KNOWLEDGE GRAPH // HOOVER

Related Hoover Tumble Dryer Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E12Tumble Dryer
Electronic Control Board (PCB) & Bus Communications
Hoover H-DRY 300 / 500 Heat-Pump & Auto Care Tumble Dryer: Serial communication timeout E12;...
Inspect Protocol
E13Tumble Dryer
General System & Mechanical Integration
Hoover H-DRY 300 / 500 Heat-Pump & Auto Care Tumble Dryer: Condensate collection container f...
Inspect Protocol
E14Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor
Hoover H-DRY 300 / 500 Heat-Pump & Auto Care Tumble Dryer: Condensate lift pump motor fault ...
Inspect Protocol
E15Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor
Hoover H-DRY 300 / 500 Heat-Pump & Auto Care Tumble Dryer: Inverter compressor driver fault ...
Inspect Protocol
E16Tumble Dryer
General System & Mechanical Integration
Hoover H-DRY 300 / 500 Heat-Pump & Auto Care Tumble Dryer: Heat pump evaporator coil freezin...
Inspect Protocol
E17Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor
Hoover H-DRY 300 / 500 Heat-Pump & Auto Care Tumble Dryer: Drum drive belt breakage detected...
Inspect Protocol
E18Tumble Dryer
General System & Mechanical Integration
Hoover H-DRY 300 / 500 Heat-Pump & Auto Care Tumble Dryer: Power supply voltage or frequency...
Inspect Protocol
E21Tumble Dryer
General System & Mechanical Integration
Hoover H-DRY 300 / 500 Heat-Pump & Auto Care Tumble Dryer: Moisture sensing calibration ampl...
Inspect Protocol
F1Tumble Dryer
NTC Temperature Sensor & Thermistor
Hoover H-DRY 300 / 500 Heat-Pump & Auto Care Tumble Dryer: Air intake temperature sensor fau...
Inspect Protocol
F2Tumble Dryer
NTC Temperature Sensor & Thermistor
Hoover H-DRY 300 / 500 Heat-Pump & Auto Care Tumble Dryer: Rear exhaust temperature sensor f...
Inspect Protocol
F3Tumble Dryer
NTC Temperature Sensor & Thermistor
Hoover H-DRY 300 / 500 Heat-Pump & Auto Care Tumble Dryer: Compressor discharge pipe high-te...
Inspect Protocol
F4Tumble Dryer
Water Level Pressure Switch & Air Dome
Hoover H-DRY 300 / 500 Heat-Pump & Auto Care Tumble Dryer: Condensate evacuation pump failur...
Inspect Protocol
F5Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor
Hoover H-DRY 300 / 500 Heat-Pump & Auto Care Tumble Dryer: Motor / compressor inverter commu...
Inspect Protocol
F6Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor
Hoover H-DRY 300 / 500 Heat-Pump & Auto Care Tumble Dryer: Auxiliary heat-pump cooling fan f...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy