Hoover E14 — Dishwasher
[ACTIVE]Hoover H-DISH 300 / 500 / 700 Maxi Tub Smart Dishwasher: Flowmeter signal missing during fill E14; pressure switch senses water rising in tub but zero flowmeter impulses arrive at PCB.
On Hoover dishwashers featuring H-DISH Maxi Tub architecture, Triple Self-Cleaning micro-filtration wash system, and hOn Wi-Fi connectivity: Jammed impeller wheel in side air-break matrix, disconnected reed switch sensor board, or broken wire harness.
Inspect flowmeter connector at left side water jacket. Test reed switch closing action with small magnet and ohmmeter. Replace sensor circuit board. Hold the Programme selector button and Start/Pause together for 6 seconds until all indicator LEDs light up, then power off.