Hoover E1 — Dishwasher
[ACTIVE]Hoover H-DISH 300 / 500 / 700 Maxi Tub Smart Dishwasher: Water inlet fill failure E1; appliance detects no incoming water flow into sump after opening fill valve.
On Hoover dishwashers utilizing H-DISH Maxi Tub architecture, Triple Self-Cleaning micro-filtration wash system, and hOn Wi-Fi connectivity: Closed water supply valve, kinked inlet hose, blocked AquaStop mesh filter, or open valve coil (~3.5–4.5 kΩ).
Check water supply tap pressure. Unscrew supply hose and clean AquaStop inlet filter screen. Measure solenoid valve coil (~3.5–4.5 kΩ). Hold the Programme selector button and Start/Pause together for 6 seconds until all indicator LEDs light up, then power off.