Hoover E3 — Dishwasher
[ACTIVE]Hoover H-DISH 300 / 500 / 700 Maxi Tub Smart Dishwasher: Drain evacuation timeout E3; water remains in sump after 240 seconds of drain pump operation.
On Hoover dishwashers powered by H-DISH Maxi Tub architecture, Triple Self-Cleaning micro-filtration wash system, and hOn Wi-Fi connectivity: Blocked microfilter, foreign body (glass shard, olive pit) jamming drain impeller, kinked hose, or open pump motor (~160–220 Ω).
Remove sump filters and clean thoroughly. Check drain pump impeller for free rotation. Measure drain pump winding resistance (~160–220 Ω). Hold the Programme selector button and Start/Pause together for 6 seconds until all indicator LEDs light up, then power off.