[ACTIVE]Hoover H-HOB Induction & Multi-Zone Flex Cooktop: Mains supply frequency out of limits F7; AC power line frequency falls outside 47 Hz–63 Hz operating window.
On Hoover cooktops utilizing H-HOB multi-zone induction power generator, IGBT inverter thermal protection, and digital touch slider control: Unstable generator or solar inverter power supply, severe grid harmonic distortion, or failed zero-crossing detection circuit on board.
Measure AC line frequency with digital multimeter (must read 50.0 Hz or 60.0 Hz ±1 Hz). If running on generator, adjust governor. Replace filter board if grid is normal. Clear cookware off the ceramic plate, turn off breaker for 45 seconds, reconnect power and press Key Lock sensor for 6 seconds.