Hoover F9 — Hob
[ACTIVE]Hoover H-HOB Induction & Multi-Zone Flex Cooktop: Induction coil current sensor calibration failure F9; current transformer sensing circuit fails zero-offset balance test at power up.
On Hoover cooktops utilizing H-HOB multi-zone induction power generator, IGBT inverter thermal protection, and digital touch slider control: Defective current transformer on power PCB, leaky shunt resistor, or cracked ferrite core on measuring coil.
Turn off breaker for 5 minutes. If code returns upon energization, inspect power board current sensing stage or replace affected generator board. Clear cookware off the ceramic plate, turn off breaker for 45 seconds, reconnect power and press Key Lock sensor for 6 seconds.