Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Ignis AL02
FAQ TREEWhat does error code AL02 mean on a Ignis appliance?
Ignis error code AL02 indicates: Ignis Combi Double Door Total NoFrost Refrigerator: Freezer evaporator defrost termination NTC sensor fault AL02; controller unable to detect coil temperature..
What is the root cause of Ignis error code AL02?
The primary root cause for Ignis code AL02 is: On Ignis refrigerators (Ignis heavy-duty electromechanical chassis and Arcadia / L1373 hybrid control architecture): Thermal shock degradation, moisture saturation inside sensor jacket during defrost cycles, or severed clip-on lead..
How do I fix or resolve Ignis error code AL02?
To resolve error code AL02: Disconnect power. Remove freezer evaporator cover. Check NTC resistance: ~2.7 kΩ at 25°C, ~16 kΩ at 0°C, ~32 kΩ at -18°C. Replace clip-on defrost sensor. Press thermostat reset or super button for 3 seconds to cancel temperature alarm and re-arm cooling.
Is it safe to clear Ignis error code AL02 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Ignis code AL02 persists, the physical component causing On Ignis refrigerators (Ignis heavy-duty electromechanical chassis and Arcadia / L1373 hybrid control architecture): Thermal shock degradation, moisture saturation inside sensor jacket during defrost cycles, or severed clip-on lead. must be inspected or replaced.
How do I test electrical resistance for Ignis code AL02 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Compressor Motor Windings (Run/Start) & Defrost Heater across Across 3 compressor pins (Common, Run, Start): R(C-S) + R(C-R) = R(S-R). Winding to earth: >20MΩ (OL).. Expected nominal reading is 15Ω–25Ω (Run C-R), 20Ω–35Ω (Start C-S), 200Ω–400Ω (Defrost Heater). PTC Relay: 10Ω–30Ω at 25°C.. Tolerance: ±10%. Any low insulation resistance to casing (<2MΩ) trips the breaker. Defrost bimetal reads <0.5Ω when sub-zero..
What safety protocol must be followed before servicing Ignis code AL02?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?



