Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEF22
Indesit
Indesit // OFFICIAL DIAGNOSTIC BENCH

Indesit Tumble Dryer F22

DryerRefrigeration Compressor, Defrost Heater & PTC Relay
High-efficiency heat pump tumble dryer with ergonomic titanium drum and digital sensor display
Dryer
Select Appliance Type
0ms Instant Telemetry Switch
Whirlpool / Indesit Group: Equivalent Code Across OEM Group Brands
Whirlpool / Indesit Global Electronic Architecture
WhirlpoolF22AristonF22HotpointF22BauknechtF22IgnisF22MaytagF22
Other Brands Sharing Code F22:BoschF22MieleF22SiemensF22NeffF22V-ZugF22LiebherrF22GaggenauF22

Symptom / Description

FAULT

Indesit MyTime & Push&Go Condenser Tumble Dryer: Heat pump compressor discharge overtemperature warning F22; high-pressure line thermistor exceeds 115°C safety ceiling.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Indesit heat pump dryers: Severely blocked bottom condenser filter choking airflow, slow evaporator blower fan, or micro-leak in R134a/R290 gas circuit.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Clean or replace lower foam condenser filter block. Vacuum aluminum heat exchanger fins. Verify secondary cooling fan operates freely during drying. Hold Start button for 5 seconds until progress lights flash, rotate selector to 0, clean lint filter.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Indesit Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Main Control PCB, Refrigeration & Sensor Bus Loop

230V AC Mains Filter, Low-Voltage SMPS DC Rails & MCU I2C/UART Bus

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III12.05 V DCVΩCOMMAIN CONTROL BOARDSMPS TRANSFORMERPRIMARY 230V / SECONDARY DC+12V DC+5V DCI2C / UART SENSOR BUS
Target Component
Compressor Motor Windings (Run/Start) & Defrost Heater
Nominal Resistance / Test Range
15Ω–25Ω (Run C-R), 20Ω–35Ω (Start C-S), 200Ω–400Ω (Defrost Heater). PTC Relay: 10Ω–30Ω at 25°C.
Test Harness Pins
Across 3 compressor pins (Common, Run, Start): R(C-S) + R(C-R) = R(S-R). Winding to earth: >20MΩ (OL).
Diagnostic Verification Rule
Verify clean DC rails without ripple. Defective SMPS capacitors or burned MCU comm bus triggers system lock.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLRefrigeration Compressor, Defrost Heater & PTC RelayTumble Dryer
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
15Ω–25Ω (Run C-R), 20Ω–35Ω (Start C-S), 200Ω–400Ω (Defrost Heater). PTC Relay: 10Ω–30Ω at 25°C.NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Compressor Motor Windings (Run/Start) & Defrost Heater
Test Pins & Connections
PROBE (+)
PROBE (-)
Across 3 compressor pins (Common, Run, Start): R(C-S) + R(C-R) = R(S-R). Winding to earth: >20MΩ (OL).
Tolerance & Diagnostic Criteria±10%. Any low insulation resistance to casing (<2MΩ) trips the breaker. Defrost bimetal reads <0.5Ω when sub-zero.
1. Pre-Intervention Electrical Safety Protocols
  • !Refrigeration Safety Protocol: Disconnect mains power before unclipping compressor terminal covers.
  • !Flammable Refrigerant Warning: R600a (isobutane) is flammable. Never puncture cooling tubes or use open flame.
  • !High Surface Temperature: Compressor shell can exceed 80°C during normal operation. Allow to cool before inspection.
3. Preliminary Mechanical & Visual Checks
  • Listen for compressor startup attempts: repetitive clicking every 60 seconds indicates locked rotor or failed PTC relay.
  • Inspect evaporator coil for thick solid frost buildup, signaling defrost heater, sensor, or timer failure.
  • Clean condenser coils and check cooling fan motor for free rotation and dust accumulation.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Indesit F22

FAQ TREE
What does error code F22 mean on a Indesit appliance?

Indesit error code F22 indicates: Indesit MyTime & Push&Go Condenser Tumble Dryer: Heat pump compressor discharge overtemperature warning F22; high-pressure line thermistor exceeds 115°C safety ceiling..

What is the root cause of Indesit error code F22?

The primary root cause for Indesit code F22 is: On Indesit heat pump dryers: Severely blocked bottom condenser filter choking airflow, slow evaporator blower fan, or micro-leak in R134a/R290 gas circuit..

How do I fix or resolve Indesit error code F22?

To resolve error code F22: Clean or replace lower foam condenser filter block. Vacuum aluminum heat exchanger fins. Verify secondary cooling fan operates freely during drying. Hold Start button for 5 seconds until progress lights flash, rotate selector to 0, clean lint filter.

Is it safe to clear Indesit error code F22 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Indesit code F22 persists, the physical component causing On Indesit heat pump dryers: Severely blocked bottom condenser filter choking airflow, slow evaporator blower fan, or micro-leak in R134a/R290 gas circuit. must be inspected or replaced.

How do I test electrical resistance for Indesit code F22 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Compressor Motor Windings (Run/Start) & Defrost Heater across Across 3 compressor pins (Common, Run, Start): R(C-S) + R(C-R) = R(S-R). Winding to earth: >20MΩ (OL).. Expected nominal reading is 15Ω–25Ω (Run C-R), 20Ω–35Ω (Start C-S), 200Ω–400Ω (Defrost Heater). PTC Relay: 10Ω–30Ω at 25°C.. Tolerance: ±10%. Any low insulation resistance to casing (<2MΩ) trips the breaker. Defrost bimetal reads <0.5Ω when sub-zero..

What safety protocol must be followed before servicing Indesit code F22?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

What does Indesit error code F22 mean on a Tumble Dryer?

Indesit error code F22 on a Tumble Dryer indicates: Indesit MyTime & Push&Go Condenser Tumble Dryer: Heat pump compressor discharge overtemperature warning F22; high-pressure line thermistor exceeds 115°C safety ceiling.. Primary cause: On Indesit heat pump dryers: Severely blocked bottom condenser filter choking airflow, slow evaporator blower fan, or micro-leak in R134a/R290 gas circuit.. Recommended solution: Clean or replace lower foam condenser filter block. Vacuum aluminum heat exchanger fins. Verify secondary cooling fan operates freely during drying. Hold Start button for 5 seconds until progress lights flash, rotate selector to 0, clean lint filter..

What does Indesit error code F22 mean on a Washing Machine?

Indesit error code F22 on a Washing Machine indicates: Indesit Innex & Push&Go MyTime Washing Machine: Motor drive inverter module overcurrent fault F22; IPM power silicon senses short circuit or excessive motor stator phase current.. Primary cause: On Indesit washing appliances: Shorted winding in 3-phase BLDC motor stator, locked drum mechanical assembly, or punctured IGBT bridge on power board.. Recommended solution: Measure resistance between motor phase pins U-V, V-W, U-W (must be symmetrical, 6.5–8.5 Ω per phase). Test for zero resistance across IGBT output terminals. Press and hold Start/Pause for 5 seconds until LEDs sequence, rotate selector to '0', and disconnect power for 60s..

Community Verification

COMMUNITY

Did this solution resolve the issue?

Indesit F22 — Multi-Appliance Technical Reference

Verified OEM diagnostic specifications across all appliance systems sharing this fault code.

Indesit F22 — Dryer

[ACTIVE]
Symptom / Description:

Indesit MyTime & Push&Go Condenser Tumble Dryer: Heat pump compressor discharge overtemperature warning F22; high-pressure line thermistor exceeds 115°C safety ceiling.

Root Cause:

On Indesit heat pump dryers: Severely blocked bottom condenser filter choking airflow, slow evaporator blower fan, or micro-leak in R134a/R290 gas circuit.

Repair Instructions:

Clean or replace lower foam condenser filter block. Vacuum aluminum heat exchanger fins. Verify secondary cooling fan operates freely during drying. Hold Start button for 5 seconds until progress lights flash, rotate selector to 0, clean lint filter.

Indesit F22 — Washing Machine

Symptom / Description:

Indesit Innex & Push&Go MyTime Washing Machine: Motor drive inverter module overcurrent fault F22; IPM power silicon senses short circuit or excessive motor stator phase current.

Root Cause:

On Indesit washing appliances: Shorted winding in 3-phase BLDC motor stator, locked drum mechanical assembly, or punctured IGBT bridge on power board.

Repair Instructions:

Measure resistance between motor phase pins U-V, V-W, U-W (must be symmetrical, 6.5–8.5 Ω per phase). Test for zero resistance across IGBT output terminals. Press and hold Start/Pause for 5 seconds until LEDs sequence, rotate selector to '0', and disconnect power for 60s.

SEMANTIC KNOWLEDGE GRAPH // INDESIT

Related Indesit Tumble Dryer Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

F23Tumble Dryer
Water Level Pressure Switch & Air Dome
Indesit MyTime & Push&Go Condenser Tumble Dryer: Lower condenser filter blockage warning F23...
Inspect Protocol
F24Tumble Dryer
Electronic Control Board (PCB) & Bus Communications
Indesit MyTime & Push&Go Condenser Tumble Dryer: Electronic humidity sensing amplifier calib...
Inspect Protocol
F01Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor
Indesit MyTime & Push&Go Condenser Tumble Dryer: Drum drive motor relay or triac failure F01...
Inspect Protocol
F02Tumble Dryer
Heating Element, Thermostat & Safety Fuse
Indesit MyTime & Push&Go Condenser Tumble Dryer: Drum drive motor stalled or thermal protect...
Inspect Protocol
F03Tumble Dryer
NTC Temperature Sensor & Thermistor
Indesit MyTime & Push&Go Condenser Tumble Dryer: Front air duct NTC thermistor fault F03; pr...
Inspect Protocol
F04Tumble Dryer
Drainage System & Drain Pump
Indesit MyTime & Push&Go Condenser Tumble Dryer: Condensate evacuation pump failure F04; wat...
Inspect Protocol
F05Tumble Dryer
Electronic Control Board (PCB) & Bus Communications
Indesit MyTime & Push&Go Condenser Tumble Dryer: Electronic moisture conductivity sensor fau...
Inspect Protocol
F06Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor
Indesit MyTime & Push&Go Condenser Tumble Dryer: Drum rotation tachometer pulse failure F06;...
Inspect Protocol
F07Tumble Dryer
Heating Element, Thermostat & Safety Fuse
Indesit MyTime & Push&Go Condenser Tumble Dryer: Heating element relay contacts welded close...
Inspect Protocol
F08Tumble Dryer
Heating Element, Thermostat & Safety Fuse
Indesit MyTime & Push&Go Condenser Tumble Dryer: Heating element open circuit or heat pump c...
Inspect Protocol
F09Tumble Dryer
Electronic Control Board (PCB) & Bus Communications
Indesit MyTime & Push&Go Condenser Tumble Dryer: Control board EEPROM configuration checksum...
Inspect Protocol
F10Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor
Indesit MyTime & Push&Go Condenser Tumble Dryer: Motor control module thermal cutoff activat...
Inspect Protocol
F11Tumble Dryer
Electronic Control Board (PCB) & Bus Communications
Indesit MyTime & Push&Go Condenser Tumble Dryer: UI to main control board serial communicati...
Inspect Protocol
F12Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor
Indesit MyTime & Push&Go Condenser Tumble Dryer: Moisture sensor electrode open circuit F12;...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy