Indesit F9 — Dishwasher
[ACTIVE]Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Continuous water fill detected F9; inlet valve fails to close or triac on power board leaks current, overfilling sump.
On Indesit dishwashers: Solenoid plunger stuck open mechanically by sand particle, or punctured triac semiconductor on main control module.
Turn off water tap. Unplug appliance. If water still flows into tub, replace dual inlet valve assembly. If stops, inspect board triac output. Press and hold Start/Reset for 5 seconds until drain pump runs, wait 60 seconds, then power cycle ON/OFF.