Kitchenaid F06 — Refrigerator / Freezer
[ACTIVE]KitchenAid Preserva French Door & Multi-Door Refrigerator: Diagnostic code F06 indicates inverter compressor driver module communication failure or locked rotor protection trip.
On Kitchenaid refrigerators (KitchenAid Architect Series precision sensors and dual-evaporator system): Blown IGBT bridge on inverter board, open phase winding on BLDC compressor (6–15 Ω across U-V, V-W, W-U), or loss of PWM control signal (50–150 Hz).
Disconnect power. Measure BLDC compressor phase-to-phase resistances (must be identical 6–15 Ω). Check 230V AC input to inverter and PWM signal from main board. Replace inverter board if motor is good. Press and hold Max Cool and FreshFlow Filter Reset pads simultaneously for 4 seconds until the control panel beeps.