Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Korting E02
FAQ TREEWhat does error code E02 mean on a Korting appliance?
Korting error code E02 indicates: Körting KGV / KGI UltraClean Fully Integrated Inverter Dishwasher: Diagnostic fault code E02 registered by the microcomputer controller. Dishwasher alternative wash zone diverter water distributor motor microswitch open.
What is the root cause of Korting error code E02?
The primary root cause for Korting code E02 is: On Körting domestic and cooking appliances engineered on Gorenje-Hisense platforms engineered with Asko/Gorenje hydraulic system, 1800W flow heater (27-31 Ω), BLDC wash pump with tachometer (70-95 Ω), magnetic drain pump (150-190 Ω), and turbidity sensor: internal ceramic disc valve seized by hard limescale, reduction gearbox tooth broken, or 230V AC coil open. Metrological tolerance verification: diverter synchronous motor coil resistance 8.5 kΩ to 11.5 kΩ; feedback switch contact resistance <0.2 Ω..
How do I fix or resolve Korting error code E02?
To resolve error code E02: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure synchronous motor resistance on diverter harness (~10 kΩ) and verify position switch clicks as motor turns. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance off at power button. Hold Program button continuously for 5 seconds while turning power switch On; wait for LED sequence to confirm reset.
Is it safe to clear Korting error code E02 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Korting code E02 persists, the physical component causing On Körting domestic and cooking appliances engineered on Gorenje-Hisense platforms engineered with Asko/Gorenje hydraulic system, 1800W flow heater (27-31 Ω), BLDC wash pump with tachometer (70-95 Ω), magnetic drain pump (150-190 Ω), and turbidity sensor: internal ceramic disc valve seized by hard limescale, reduction gearbox tooth broken, or 230V AC coil open. Metrological tolerance verification: diverter synchronous motor coil resistance 8.5 kΩ to 11.5 kΩ; feedback switch contact resistance <0.2 Ω. must be inspected or replaced.
How do I test electrical resistance for Korting code E02 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..
What safety protocol must be followed before servicing Korting code E02?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?



