Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEE02
Korting
Korting // OFFICIAL DIAGNOSTIC BENCH

Korting Dishwasher E02

DishwasherDrainage System & Drain Pump
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Vestel / European OEM Group: Equivalent Code Across OEM Group Brands
Vestel OEM Shared Chassis & Multi-Brand Architecture
VestelE02Schaub LorenzE02AlaskaE02BlueskyE02NovomaticF02SekomE02
Other Brands Sharing Code E02:BoschE02SiemensE02SamsungE02LGE02ElectroluxE02AEGE02BekoE02HaierE02CandyE02NeffE02

Symptom / Description

FAULT

Körting KGV / KGI UltraClean Fully Integrated Inverter Dishwasher: Diagnostic fault code E02 registered by the microcomputer controller. Dishwasher alternative wash zone diverter water distributor motor microswitch open

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Körting domestic and cooking appliances engineered on Gorenje-Hisense platforms engineered with Asko/Gorenje hydraulic system, 1800W flow heater (27-31 Ω), BLDC wash pump with tachometer (70-95 Ω), magnetic drain pump (150-190 Ω), and turbidity sensor: internal ceramic disc valve seized by hard limescale, reduction gearbox tooth broken, or 230V AC coil open. Metrological tolerance verification: diverter synchronous motor coil resistance 8.5 kΩ to 11.5 kΩ; feedback switch contact resistance <0.2 Ω.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure synchronous motor resistance on diverter harness (~10 kΩ) and verify position switch clicks as motor turns. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance off at power button. Hold Program button continuously for 5 seconds while turning power switch On; wait for LED sequence to confirm reset.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Korting Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Hydraulic & Drainage Loop

Drain Pump M2, Impeller Chamber, Sump Filter & Analog Pressostat

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III168.4 ΩVΩCOMDRAIN PUMP M2DRAIN OUTFLOWRATED COIL: 150-280Ω
Target Component
Drain Pump Motor Stator Coils
Nominal Resistance / Test Range
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)
Test Harness Pins
Across pump motor spade terminals (L-N unclipped)
Diagnostic Verification Rule
Measure coil resistance unplugged. If OL (open loop) or < 50 Ω (shorted), replace pump assembly.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDrainage System & Drain PumpDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Drain Pump Motor Stator Coils
Test Pins & Connections
PROBE (+)
PROBE (-)
Across pump motor spade terminals (L-N unclipped)
Tolerance & Diagnostic Criteria±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Isolate 230V mains power before accessing the lower pump housing.
  • !Prepare a shallow basin and absorption towels: expect 3 to 10 liters of stagnant trapped water upon filter opening.
  • !Beware of sharp foreign objects (broken glass, needles, screws) trapped inside the impeller cavity.
3. Preliminary Mechanical & Visual Checks
  • Unscrew coin trap filter and clear all foreign debris (coins, hairpins, bra underwires).
  • Rotate pump impeller manually: synchronous magnetic rotors should snap cleanly in 90° intervals without jamming.
  • Check drain hose for kinks, blockages, or unpunched sink spigots; verify drain height is between 65cm and 100cm.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Korting E02

FAQ TREE
What does error code E02 mean on a Korting appliance?

Korting error code E02 indicates: Körting KGV / KGI UltraClean Fully Integrated Inverter Dishwasher: Diagnostic fault code E02 registered by the microcomputer controller. Dishwasher alternative wash zone diverter water distributor motor microswitch open.

What is the root cause of Korting error code E02?

The primary root cause for Korting code E02 is: On Körting domestic and cooking appliances engineered on Gorenje-Hisense platforms engineered with Asko/Gorenje hydraulic system, 1800W flow heater (27-31 Ω), BLDC wash pump with tachometer (70-95 Ω), magnetic drain pump (150-190 Ω), and turbidity sensor: internal ceramic disc valve seized by hard limescale, reduction gearbox tooth broken, or 230V AC coil open. Metrological tolerance verification: diverter synchronous motor coil resistance 8.5 kΩ to 11.5 kΩ; feedback switch contact resistance <0.2 Ω..

How do I fix or resolve Korting error code E02?

To resolve error code E02: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure synchronous motor resistance on diverter harness (~10 kΩ) and verify position switch clicks as motor turns. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance off at power button. Hold Program button continuously for 5 seconds while turning power switch On; wait for LED sequence to confirm reset.

Is it safe to clear Korting error code E02 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Korting code E02 persists, the physical component causing On Körting domestic and cooking appliances engineered on Gorenje-Hisense platforms engineered with Asko/Gorenje hydraulic system, 1800W flow heater (27-31 Ω), BLDC wash pump with tachometer (70-95 Ω), magnetic drain pump (150-190 Ω), and turbidity sensor: internal ceramic disc valve seized by hard limescale, reduction gearbox tooth broken, or 230V AC coil open. Metrological tolerance verification: diverter synchronous motor coil resistance 8.5 kΩ to 11.5 kΩ; feedback switch contact resistance <0.2 Ω. must be inspected or replaced.

How do I test electrical resistance for Korting code E02 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..

What safety protocol must be followed before servicing Korting code E02?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // KORTING

Related Korting Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E03Dishwasher
Drainage System & Drain Pump
Körting KGV / KGI UltraClean Fully Integrated Inverter Dishwasher: Diagnostic fault code E03...
Inspect Protocol
E04Dishwasher
Drainage System & Drain Pump
Körting KGV / KGI UltraClean Fully Integrated Inverter Dishwasher: Diagnostic fault code E04...
Inspect Protocol
E05Dishwasher
Drainage System & Drain Pump
Körting KGV / KGI UltraClean Fully Integrated Inverter Dishwasher: Diagnostic fault code E05...
Inspect Protocol
E06Dishwasher
Drainage System & Drain Pump
Körting KGV / KGI UltraClean Fully Integrated Inverter Dishwasher: Diagnostic fault code E06...
Inspect Protocol
E07Dishwasher
Drainage System & Drain Pump
Körting KGV / KGI UltraClean Fully Integrated Inverter Dishwasher: Diagnostic fault code E07...
Inspect Protocol
E08Dishwasher
Drainage System & Drain Pump
Körting KGV / KGI UltraClean Fully Integrated Inverter Dishwasher: Diagnostic fault code E08...
Inspect Protocol
E09Dishwasher
Water Level Pressure Switch & Air Dome
Körting KGV / KGI UltraClean Fully Integrated Inverter Dishwasher: Diagnostic fault code E09...
Inspect Protocol
E1Dishwasher
Drainage System & Drain Pump
Körting KGV / KGI UltraClean Fully Integrated Inverter Dishwasher: Diagnostic fault code E1 ...
Inspect Protocol
F06_DWDishwasher
Drainage System & Drain Pump
Körting KGV / KGI UltraClean Fully Integrated Inverter Dishwasher: Diagnostic fault code F06...
Inspect Protocol
F10Dishwasher
Water Level Pressure Switch & Air Dome
Körting KGV / KGI UltraClean Fully Integrated Inverter Dishwasher: Diagnostic fault code F10...
Inspect Protocol
F11Dishwasher
Drainage System & Drain Pump
Körting KGV / KGI UltraClean Fully Integrated Inverter Dishwasher: Diagnostic fault code F11...
Inspect Protocol
F12_DWDishwasher
Drainage System & Drain Pump
Körting KGV / KGI UltraClean Fully Integrated Inverter Dishwasher: Diagnostic fault code F12...
Inspect Protocol
F13_DWDishwasher
Drainage System & Drain Pump
Körting KGV / KGI UltraClean Fully Integrated Inverter Dishwasher: Diagnostic fault code F13...
Inspect Protocol
F17_DWDishwasher
Drainage System & Drain Pump
Körting KGV / KGI UltraClean Fully Integrated Inverter Dishwasher: Diagnostic fault code F17...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy