Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Miele F118
FAQ TREEWhat does error code F118 mean on a Miele appliance?
Miele error code F118 indicates: The operation of the second additional compartment is erratic, and the error code F118 is present..
What is the root cause of Miele error code F118?
The primary root cause for Miele code F118 is: The second specialized compartment evaporator temperature sensor is out of service..
How do I fix or resolve Miele error code F118?
To resolve error code F118: After turning off the unit, locate the evaporator and the corresponding probe for the second compartment. Measure the resistance of the probe. If the reading confirms a failure, replacement of the part is required.
Is it safe to clear Miele error code F118 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Miele code F118 persists, the physical component causing The second specialized compartment evaporator temperature sensor is out of service. must be inspected or replaced.
How do I test electrical resistance for Miele code F118 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..
What safety protocol must be followed before servicing Miele code F118?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?