OFFICIAL FAULT CODEF152
Miele
Miele // OFFICIAL DIAGNOSTIC BENCH

Miele F152

DishwasherWater Inlet Valve, Aquastop & Flowmeter
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher

Symptom / Description

FAULT

The gas appliance does not start because the gas supply seems blocked, preventing the burner from igniting.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

An electrical fault has been detected in the gas solenoid valve coil. The latter does not receive the opening order or is mechanically blocked.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Turn off the electrical power and gas supply to the appliance. 2. Locate the gas solenoid valve and carefully examine its coil electrical connections. 3. A technician can test the coil for continuity with a multimeter; a lack of continuity indicates that it is cut. 4. Replacing the coil or the complete solenoid valve is an operation that must be carried out by a certified gas professional.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Miele Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLWater Inlet Valve, Aquastop & FlowmeterDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
3.5kΩ–4.5kΩ (Standard 230V) / 2.0kΩ–4.2kΩ (Aquastop)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Solenoid Valve Coil / Aquastop Pneumatic Valve
Test Pins & Connections
PROBE (+)
PROBE (-)
Across coil spade terminals (disconnect harness first)
Tolerance & Diagnostic Criteria±10%. Open circuit (OL) indicates burned solenoid coil. Flowmeter turbine reed switch pulses on flow.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect electrical power before touching solenoid valve coils or Aquastop connectors.
  • !Firmly shut off the domc water supply tap before unscrewing the inlet hose fitting.
  • !Check safety base drip tray for accumulated water triggering the anti-flood polystyrene float switch.
3. Preliminary Mechanical & Visual Checks
  • Remove and clean sediment and sand particles from the 3/4" inlet hose metal mesh filter.
  • Verify domestic dynamic water pressure is between 1.0 and 10.0 bar (0.1 to 1.0 MPa).
  • Inspect outer Aquastop hose jacket for expansion, pinch damage, or internal leak reservoir triggering.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Miele F152

FAQ TREE
What does error code F152 mean on a Miele appliance?

Miele error code F152 indicates: The gas appliance does not start because the gas supply seems blocked, preventing the burner from igniting..

What is the root cause of Miele error code F152?

The primary root cause for Miele code F152 is: An electrical fault has been detected in the gas solenoid valve coil. The latter does not receive the opening order or is mechanically blocked..

How do I fix or resolve Miele error code F152?

To resolve error code F152: 1. Turn off the electrical power and gas supply to the appliance. 2. Locate the gas solenoid valve and carefully examine its coil electrical connections. 3. A technician can test the coil for continuity with a multimeter; a lack of continuity indicates that it is cut. 4. Replacing the coil or the complete solenoid valve is an operation that must be carried out by a certified gas professional.

Is it safe to clear Miele error code F152 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Miele code F152 persists, the physical component causing An electrical fault has been detected in the gas solenoid valve coil. The latter does not receive the opening order or is mechanically blocked. must be inspected or replaced.

How do I test electrical resistance for Miele code F152 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Solenoid Valve Coil / Aquastop Pneumatic Valve across Across coil spade terminals (disconnect harness first). Expected nominal reading is 3.5kΩ–4.5kΩ (Standard 230V) / 2.0kΩ–4.2kΩ (Aquastop). Tolerance: ±10%. Open circuit (OL) indicates burned solenoid coil. Flowmeter turbine reed switch pulses on flow..

What safety protocol must be followed before servicing Miele code F152?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // MIELE

Related Miele Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

F153NTC Temperature Sensor & Thermistor
The gas dryer stops mid-cycle and reports excessive temperature in the heating system.
Inspect Protocol
F154Electronic Control Board (PCB) & Bus Communications
The device does not start any programs and displays a critical system error code.
Inspect Protocol
F155Water Inlet Valve, Aquastop & Flowmeter
The device goes into safety mode and refuses to start, signaling the presence of a flame eve...
Inspect Protocol
F156NTC Temperature Sensor & Thermistor
The dryer stops mid-program or does not heat at all.
Inspect Protocol
F157NTC Temperature Sensor & Thermistor
The drying program does not heat or terminates prematurely with an error code.
Inspect Protocol
F158General System & Mechanical Integration
The appliance (heat pump dryer, refrigerator) stops working and the compressor may seem exce...
Inspect Protocol
F19Water Level Pressure Switch & Air Dome
Miele F19: Water inlet / filling timeout in Dishwasher; appliance fails to fill to minimum o...
Inspect Protocol
F2NTC Temperature Sensor & Thermistor
The water does not heat up or, on the contrary, overheats, leading to the program stopping a...
Inspect Protocol
F22NTC Temperature Sensor & Thermistor
NTC sensor fault (bottom temperature)
Inspect Protocol
F24Heating Element, Thermostat & Safety Fuse
Miele F24: Water/air heating failure in Dishwasher; heating circuit does not reach set tempe...
Inspect Protocol
F3NTC Temperature Sensor & Thermistor
In a dryer or oven, the appliance does not heat or heats uncontrollably, then the cycle stops.
Inspect Protocol
F38Electronic Control Board (PCB) & Bus Communications
The device does not start and immediately displays a system error, often after servicing or ...
Inspect Protocol
F39Electronic Control Board (PCB) & Bus Communications
General device malfunction, controls become unresponsive or a critical error is displayed on...
Inspect Protocol
F4NTC Temperature Sensor & Thermistor
The drying or cooking program ends prematurely, the appliance does not produce heat and the ...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy