OFFICIAL FAULT CODEF160
Miele
Miele // OFFICIAL DIAGNOSTIC BENCH

Miele F160

RefrigeratorNTC Temperature Sensor & Thermistor
Monolithic French-door smart refrigerator in matte black steel with dual refrigeration zones
Refrigerator
Select Appliance Type
0ms Instant Telemetry Switch

Symptom / Description

FAULT

Faulty cabinet temperature sensor signal in wine conditioning zone 1.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

The NTC cabinet temperature probe assigned to zone 1 transmits an out-of-range resistance value due to a sensor fault or harness break.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Disconnect mains power, access the sensor harness for zone 1, inspect the connector pins, and measure the NTC probe resistance with a multimeter (nominal: 5kΩ–15kΩ at 20°C). Replace the probe if out of range.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Miele Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorRefrigerator / Freezer
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Miele F160

FAQ TREE
What does error code F160 mean on a Miele appliance?

Miele error code F160 indicates: Faulty cabinet temperature sensor signal in wine conditioning zone 1..

What is the root cause of Miele error code F160?

The primary root cause for Miele code F160 is: The NTC cabinet temperature probe assigned to zone 1 transmits an out-of-range resistance value due to a sensor fault or harness break..

How do I fix or resolve Miele error code F160?

To resolve error code F160: Disconnect mains power, access the sensor harness for zone 1, inspect the connector pins, and measure the NTC probe resistance with a multimeter (nominal: 5kΩ–15kΩ at 20°C). Replace the probe if out of range.

Is it safe to clear Miele error code F160 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Miele code F160 persists, the physical component causing The NTC cabinet temperature probe assigned to zone 1 transmits an out-of-range resistance value due to a sensor fault or harness break. must be inspected or replaced.

How do I test electrical resistance for Miele code F160 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Miele code F160?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // MIELE

Related Miele Refrigerator / Freezer Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

F2Refrigeration Compressor, Defrost Heater & PTC Relay
Freezer evaporator sensor fault
Inspect Protocol
F3Electronic Control Board (PCB) & Bus Communications
Miele F3: Operational cycle fault detected during Refrigerator / Freezer program execution.
Inspect Protocol
F4NTC Temperature Sensor & Thermistor
Miele F4: NTC temperature sensor signal out of range (open or short circuit) in Refrigerator...
Inspect Protocol
AL01Refrigeration Compressor, Defrost Heater & PTC Relay
Refrigerator compartment too warm
Inspect Protocol
AL02Refrigeration Compressor, Defrost Heater & PTC Relay
Freezer compartment too warm
Inspect Protocol
F0NTC Temperature Sensor & Thermistor
Miele F0: NTC temperature sensor signal out of range (open or short circuit) in Refrigerator...
Inspect Protocol
F1NTC Temperature Sensor & Thermistor
Miele F1: NTC temperature sensor signal out of range (open or short circuit) in Refrigerator...
Inspect Protocol
F161NTC Temperature Sensor & Thermistor
Faulty cabinet temperature sensor signal in wine conditioning zone 2.
Inspect Protocol
F162NTC Temperature Sensor & Thermistor
Faulty cabinet temperature sensor signal in wine conditioning zone 3.
Inspect Protocol
F163NTC Temperature Sensor & Thermistor
Faulty evaporator temperature sensor signal in wine conditioning zone 1.
Inspect Protocol
F164NTC Temperature Sensor & Thermistor
Faulty evaporator temperature sensor signal in wine conditioning zone 2.
Inspect Protocol
F165NTC Temperature Sensor & Thermistor
Faulty evaporator temperature sensor signal in wine conditioning zone 3.
Inspect Protocol
F166NTC Temperature Sensor & Thermistor
Faulty cabinet temperature sensor signal in wine conditioning zone EWB.
Inspect Protocol
F167Electronic Control Board (PCB) & Bus Communications
Temperature alarm wine zone1
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy