Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEF182
Miele
Miele // OFFICIAL DIAGNOSTIC BENCH

Miele F182

Washing MachineNTC Temperature Sensor & Thermistor
Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum
Washing Machine
Select Appliance Type
0ms Instant Telemetry Switch

Symptom / Description

FAULT

The lower oven catalytic system is inoperative and an error is displayed, especially during cleaning cycles.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

The PT1000 temperature sensor associated with the lower oven catalytic converter is short-circuited.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Turn off the power to the device. Locate the catalyst probe, often near the ventilation system. Examine its wiring for signs of a short circuit. Test the probe using an ohmmeter; if it is confirmed to be shorted, it must be replaced.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Miele Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorWashing Machine
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Miele F182

FAQ TREE
What does error code F182 mean on a Miele appliance?

Miele error code F182 indicates: The lower oven catalytic system is inoperative and an error is displayed, especially during cleaning cycles..

What is the root cause of Miele error code F182?

The primary root cause for Miele code F182 is: The PT1000 temperature sensor associated with the lower oven catalytic converter is short-circuited..

How do I fix or resolve Miele error code F182?

To resolve error code F182: Turn off the power to the device. Locate the catalyst probe, often near the ventilation system. Examine its wiring for signs of a short circuit. Test the probe using an ohmmeter; if it is confirmed to be shorted, it must be replaced.

Is it safe to clear Miele error code F182 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Miele code F182 persists, the physical component causing The PT1000 temperature sensor associated with the lower oven catalytic converter is short-circuited. must be inspected or replaced.

How do I test electrical resistance for Miele code F182 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Miele code F182?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // MIELE

Related Miele Washing Machine Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

F183NTC Temperature Sensor & Thermistor
The lower oven reports an error and cooking odors are no longer properly filtered because th...
Inspect Protocol
F184NTC Temperature Sensor & Thermistor
The lower oven pyrolysis cleaning program does not start or is interrupted before reaching t...
Inspect Protocol
F185Door Lock Mechanism & Safety Interlock
The lower oven refuses to start a high temperature cycle (e.g. pyrolysis), indicating a prob...
Inspect Protocol
F186Drive Motor, Inverter & Tachometer Sensor
It is impossible to start a program requiring the lower oven door to be locked, such as pyro...
Inspect Protocol
F187Drive Motor, Inverter & Tachometer Sensor
The lower oven door remains stuck in the closed position after one cycle, even after the app...
Inspect Protocol
F188Drive Motor, Inverter & Tachometer Sensor
The lower oven rotisserie function is unusable and immediately triggers an error code when s...
Inspect Protocol
F189Electronic Control Board (PCB) & Bus Communications
The lower oven shuts down and displays an error, indicating that an internal process took to...
Inspect Protocol
F190Water Inlet Valve, Aquastop & Flowmeter
The appliance, typically a steam oven, displays an F190 error and refuses to start, indicati...
Inspect Protocol
F191NTC Temperature Sensor & Thermistor
Specific cooking functions do not work properly and temperature regulation appears to be fau...
Inspect Protocol
F192NTC Temperature Sensor & Thermistor
The oven displays incorrect temperature readings or does not heat, especially with advanced ...
Inspect Protocol
F193NTC Temperature Sensor & Thermistor
Cooking from the bottom is ineffective or excessive, as the oven is unable to regulate the h...
Inspect Protocol
F194NTC Temperature Sensor & Thermistor
The bottom heat is weak or non-existent, resulting in uneven cooking of dishes (undercooked ...
Inspect Protocol
F195Electronic Control Board (PCB) & Bus Communications
The wireless cooking probe does not transmit temperature information to the oven, making thi...
Inspect Protocol
F196Water Level Pressure Switch & Air Dome
The appliance (steam oven or dishwasher) stops during the cycle and reports an anomaly linke...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy