Miele F4044 — Dishwasher
[ACTIVE]The device does not heat or overheats, with an error code related to the temperature probe.
The NTC 1 temperature probe is short-circuited, sending incorrect temperature information to the electronic card.
Unplug the device. Locate the NTC 1 probe and measure its resistance. A value close to zero Ohm confirms the short circuit. Replace the probe.