Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEF4045
Miele
Miele // OFFICIAL DIAGNOSTIC BENCH

Miele Dishwasher F4045

DishwasherNTC Temperature Sensor & Thermistor
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Select Appliance Type
0ms Instant Telemetry Switch

Symptom / Description

FAULT

Temperature control no longer works and an NTC error code is displayed.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

The NTC 1 temperature probe circuit is open (cut wire, faulty probe), so no temperature information is transmitted.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Turn off the power. Check the connection of the NTC probe 1. Test its resistance with a multimeter; infinite resistance indicates an open circuit and the need to replace the probe.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Miele Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Thermal & Heating Loop

Calrod Heating Element R1, Safety Klixon & NTC Thermistor Probe

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III24.6 ΩVΩCOMHEATING ELEMENT R1HEATER R1: 20-28 ΩSAFETY THERMOSTAT (KLIXON)NTC SENSOR (4.8-12kΩ)
Target Component
NTC Temperature Sensor Probe (Thermistor)
Nominal Resistance / Test Range
4.8kΩ–12kΩ (at 20°C–25°C)
Test Harness Pins
Across sensor pins 1-2 (unplugged harness)
Diagnostic Verification Rule
Zero or OL indicates open heating element or tripped safety thermostat. Check insulation to earth.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Miele F4045

FAQ TREE
What does error code F4045 mean on a Miele appliance?

Miele error code F4045 indicates: Temperature control no longer works and an NTC error code is displayed..

What is the root cause of Miele error code F4045?

The primary root cause for Miele code F4045 is: The NTC 1 temperature probe circuit is open (cut wire, faulty probe), so no temperature information is transmitted..

How do I fix or resolve Miele error code F4045?

To resolve error code F4045: Turn off the power. Check the connection of the NTC probe 1. Test its resistance with a multimeter; infinite resistance indicates an open circuit and the need to replace the probe.

Is it safe to clear Miele error code F4045 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Miele code F4045 persists, the physical component causing The NTC 1 temperature probe circuit is open (cut wire, faulty probe), so no temperature information is transmitted. must be inspected or replaced.

How do I test electrical resistance for Miele code F4045 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Miele code F4045?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

What does Miele error code F4045 mean on a Dishwasher?

Miele error code F4045 on a Dishwasher indicates: Temperature control no longer works and an NTC error code is displayed.. Primary cause: The NTC 1 temperature probe circuit is open (cut wire, faulty probe), so no temperature information is transmitted.. Recommended solution: Turn off the power. Check the connection of the NTC probe 1. Test its resistance with a multimeter; infinite resistance indicates an open circuit and the need to replace the probe..

What does Miele error code F4045 mean on a Tumble Dryer?

Miele error code F4045 on a Tumble Dryer indicates: Temperature control no longer works and an NTC error code is displayed.. Primary cause: The NTC 1 temperature probe circuit is open (cut wire, faulty probe), so no temperature information is transmitted.. Recommended solution: Turn off the power. Check the connection of the NTC probe 1. Test its resistance with a multimeter; infinite resistance indicates an open circuit and the need to replace the probe..

Community Verification

COMMUNITY

Did this solution resolve the issue?

Miele F4045 — Multi-Appliance Technical Reference

Verified OEM diagnostic specifications across all appliance systems sharing this fault code.

Miele F4045 — Dishwasher

[ACTIVE]
Symptom / Description:

Temperature control no longer works and an NTC error code is displayed.

Root Cause:

The NTC 1 temperature probe circuit is open (cut wire, faulty probe), so no temperature information is transmitted.

Repair Instructions:

Turn off the power. Check the connection of the NTC probe 1. Test its resistance with a multimeter; infinite resistance indicates an open circuit and the need to replace the probe.

Miele F4045 — Dryer

Symptom / Description:

Temperature control no longer works and an NTC error code is displayed.

Root Cause:

The NTC 1 temperature probe circuit is open (cut wire, faulty probe), so no temperature information is transmitted.

Repair Instructions:

Turn off the power. Check the connection of the NTC probe 1. Test its resistance with a multimeter; infinite resistance indicates an open circuit and the need to replace the probe.

SEMANTIC KNOWLEDGE GRAPH // MIELE

Related Miele Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

F4046Dishwasher
NTC Temperature Sensor & Thermistor
A temperature or drying malfunction is noted, with an error pointing to the NTC 2 probe.
Inspect Protocol
F4047Dishwasher
NTC Temperature Sensor & Thermistor
A temperature-related device function has failed, with code F4047 displayed.
Inspect Protocol
F4048Dishwasher
Drainage System & Drain Pump
The device no longer drains its water or, on the contrary, the water flows directly without ...
Inspect Protocol
F4049Dishwasher
Drainage System & Drain Pump
Draining is very slow and water remains in the tank at the end of the cycle.
Inspect Protocol
F4050Dishwasher
Drainage System & Drain Pump
A water leak is visible under the appliance, particularly during the filling and washing pha...
Inspect Protocol
F4051Dishwasher
Drive Motor, Inverter & Tachometer Sensor
The motor does not start, runs erratically, or the unit displays a communications error code.
Inspect Protocol
F4052Dishwasher
Electronic Control Board (PCB) & Bus Communications
A specific function of the device (e.g. product dosing) has failed, with an MFM1 error.
Inspect Protocol
F4053Dishwasher
Electronic Control Board (PCB) & Bus Communications
A subsystem of the machine has failed, and the code F4053 is displayed on the screen.
Inspect Protocol
F4054Dishwasher
Electronic Control Board (PCB) & Bus Communications
A specific function is inoperative and the device self-diagnosis reports an error on the MFM...
Inspect Protocol
F4055Dishwasher
Electronic Control Board (PCB) & Bus Communications
The device displays the code F4055 and a function, often an advanced option, no longer respo...
Inspect Protocol
F4056Dishwasher
Electronic Control Board (PCB) & Bus Communications
The device reports a fault on the MFM5 module, causing a specific operation to fail.
Inspect Protocol
F4057Dishwasher
Drive Motor, Inverter & Tachometer Sensor
The drum does not spin at all, or revs up to full speed before suddenly stopping.
Inspect Protocol
F4058Dishwasher
Drive Motor, Inverter & Tachometer Sensor
The engine has difficulty starting, runs slowly or erratically.
Inspect Protocol
F4059Dishwasher
Door Lock Mechanism & Safety Interlock
The door does not unlock and an error code specific to the unlock circuit is displayed.
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy